Access Channel Number
Access Channel Power
Add Info
This field defines the channel number for the signal that initiates a call from the
MS to the MTX.
Valid Entry Range: 1 through 2023
NMT Frames Affected: 3d, 3dTA2, 4b, 4bTA2, 10aAC
Operating Considerations
This field is only used with the STD900 standard.
This setting affects the RF generator and analyzer frequencies used when the
TCHAN AC and RCHAN AC commands are used.
See Also
Calling Channel Number field description, on page 371
This channel's power setting. Each power setting represents one of the four
available levels allowed by the NMT standards.
Valid Entry Range: 0 through 3
NMT Frames Affected: 3d, 3dTA2, 4b, 4bTA2, 10aAC.
Operating Considerations
This field is only used with the STD900 standard.
The additional information field contains various types of information, depending
on the frame type. Several frame types contain additional information digits in the
form H1 to H10, as outlined in the NMT system standards.
The following table shows the relationship between the
fields, and how they are used in frame data. (The H1 to H10 designations
Save
correspond to the frame digit assignments shown in the
NMT DOC. 900-1, Jan. 1985 standards.)
Chapter 10, Signaling Encoder (AF Generator 2)
Nordic Mobile Telephone (NMT) Encoder
Add Info
, %, and
Bate
367