Download Print this page

Advertisement

Operating and installation instructions
Cooker hoods
DA 196-2
DA 199-2
GiWO
To avoid the risk of accidents or
damage to the appliance it is
to read these instructions
before it is installed or used for the first time.
M.-Nr. 05 609 480

Advertisement

loading

Summary of Contents for Miele DA 196-2

  • Page 1 Operating and installation instructions Cooker hoods DA 196-2 DA 199-2 GiWO To avoid the risk of accidents or damage to the appliance it is to read these instructions before it is installed or used for the first time. M.-Nr. 05 609 480...
  • Page 2: Table Of Contents

    ......... . 3 .
  • Page 3 Old appliances contain materials which can be reclaimed or recycled. Please The transport and protective packing contact your dealer, your local waste has been selected from materials which collection centre or scrap merchant are environmentally friendly for disposal about potential recycling schemes. and can normally be recycled.
  • Page 4 Any damage which may be caused by This appliance complies with all rele- cockroaches or other vermin will not be vant legal safety requirements. Inap- covered by the appliance guarantee. propriate use can, however, lead to personal injury and damage to prop- erty.
  • Page 5 This equipment is not designed for maritime use or for use in mobile Never use an open flame beneath installations such as caravans, aircraft the cooker hood. To avoid the dan- etc. However it may be suitable for ger of fire, do not flambé or grill over an such usage subject to a risk assess- open flame under the cooker hood.
  • Page 6 These can be obtained from the Miele tion ducting. When used in extraction Spare Parts department or from build- mode, the appliance draws air in from ers’...
  • Page 7 In order to ensure safe operation, and If adequate ventilation can only be to prevent gases given off by the heat- achieved through an open window, a ing appliances from being drawn back window contact switch must be fitted. into the room when the extractor and This ensures that the hood can only be the heater are in operation simulta- operated when the window is opened...
  • Page 8 a Extension piece h Sliding switch for the lighting b Tower i Sliding switch for the fan c Canopy j Sliding switch for the power setting d Sliding switches e Sliding switches f Lighting for hob g Grease filters...
  • Page 9 ^ Set the sliding switch for the fan i The hob lighting h can be switched on to "1". and off independently of the fan. The cooker hood will run at the "0" – lighting off powersetting most recently selected. "1"...
  • Page 10 The non-return flap is designed to pre- Charcoal filters are available to order vent the exchange of room and outside through your Dealer or the Miele Spare air taking place. Parts Dept (see back cover for contact This flap is closed when the cooker details and "Technical data"...
  • Page 11 – the screw-out fuse is removed (in A microfibre "E-Cloth" is available from countries where this is applicable). the Miele UK Spare Parts Department, Part Number 98013530, which is suit- able for cleaning surfaces such as stainless steel, glass, plastic and Warning: The surfaces are suscepti- chrome.
  • Page 12: Grease Filters

    However, this will not affect Active charcoal filters can be ob- the functioning of the grease filters in tained from your dealer or the Miele any way. Spare Parts Department. ^ After cleaning leave the filters to dry Refer to the section "Technical data"...
  • Page 13 If the lighting is not working the light tube and/or starter may need changing. Disconnect the cooker hood from the mains supply. Ensure that: – it is switched off at the wall socket and the plug has been withdrawn (do not pull on the cable, only on the plug), or –...
  • Page 14 Safety regulations prohibit the fitting of this cooker hood over a solid fuel stove. For safety reasons a must be maintained be- tween the top of the hob / cooker and the bottom of the cooker hood: – 450 mm above electric hobs / cookers –...
  • Page 15 The shaded area represents the wall or ceiling area for the vent cut-out, and for fitting the connection socket. (For recirculation mode the connection socket may only be fitted in a wall area). Connection for extraction C 125 mm...
  • Page 17 (for recirculation mode only) for use when fitting the tower. for securing the retaining plates and the canopy. (for recirculation mode only) for con- necting the directional unit to the ex- haust socket on the motor unit. for securing the motor unit.
  • Page 18 There are three retaining plates A, B and the lower rim of the cooker hood. C for fixing the cooker hood to the wall. ^ DA 196-2: First of all drill the holes for attaching the Drill an 8 mm C hole on the middle canopy and for fitting retaining plate A.
  • Page 19 ^ Hold retaining plate B to the wall and push up until it is directly below the ceiling. Use the notches and the mid- dle line to align it horizontally. Mark the 4 drill holes on the wall. ^ Drill two C 8 mm holes into the wall, and push the S8 plugs into the holes.
  • Page 20 (see relevant section in "Cleaning and care"). ^ Secure the canopy with 5 x 40 mm screws into each drilled hole. ^ DA 196-2: Secure the canopy with a 5 x 40 mm screw. ^ DA 199-2: ^ Hang the canopy on the angle brack- Secure the canopy with two 5 x 40 mm screws.
  • Page 21: Retaining Plates

    ^ If a non-return valve is not present in the venting system the non-return flap supplied must be fitted onto the exhaust connection in the motor unit. The flaps must open upwards. ^ First loosely screw the two self tap- ping nuts onto the threaded bolts on retaining plate A.
  • Page 22: Recirculation

    If site conditions are not suitable for the cooker hood to be used for air extrac- tion the appliance must be connected for recirculation. ^ First push the 6 pole plugs on the canopy connection cable into the ter- minals on the motor unit. ^ Push the directional unit on to the top ^ Push the cable into the groove shown.
  • Page 23 ^ Before fitting the extension piece re- move the protective foil. An extension piece allows the cooker hood to be fitted at varying distances from the ceiling (see section "Appliance dimensions"). The extension piece has an opening at each side. These are needed for venti- lation when the appliance is being used in recirculation mode.
  • Page 24 For recirculation make sure that the openings in the extension piece are po- sitioned at the same height as the air outlets in the directional unit of the fan motor. The paper protective sheets protect the extension piece from being scratched when the tower is fitted.
  • Page 25: Extension Piece

    ^ Before fitting the extension piece re- move the protective foil from the pro- tective sheets. ^ Now secure the tower on both sides with 2 screws 3.9 x 7.5 mm. ^ Remove the protective foil from the canopy. ^ Hold the tower gently apart and fit it over the extension piece.
  • Page 26 – Where ducting is horizontal, it must Important: To avoid the danger of be laid to slope away at at least 1 cm toxic fumes please observe the per metre. Warning and Safety instructions. This is to ensure that condensate This is especially crucial when using cannot drain back into the cooker the cooker hood at the same time as...
  • Page 27: Condensate Trap

    If the exhaust ducting is to run through rooms, ceiling space etc. where there may be great variations in temperature between the different areas, the prob- lem of condensation will need to be ad- dressed.The exhaust ducting will need to be suitably insulated. In addition to insulating the exhaust ducting, we recommend that a suitable condensate trap is also installed to col-...
  • Page 28 For extra safety it is advisable to install All electrical work should be under- a residual current device (RCD) with a taken by a suitably qualified and trip current of 30 mA (in accordance competent person in strict accor- with DIN VDE 0664, VDE 0100 Sec- dance with national and local safety tion 739).
  • Page 29 The wires in the mains lead are col- oured in accordance with the following code: Green/yellow = earth Blue = neutral Brown = live If the appliance is to be connected via a plug and socket, please note the fol- lowing: As the colours of the wires in the mains lead of this appliance may not corre-...
  • Page 30 In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee please contact: – Your Miele Dealer – The Service Department (see back cover for address). When contacting the Service Depart- ment, please quote the model and se-...
  • Page 31 Unrestricted....560 m – DA 196-2....15 W –...
  • Page 32 Änderungen vorbehalten / 0604 M.-Nr. 05 609 480 / V02 Dieses Papier besteht aus 100% chlorfrei gebleichtem Zellstoff und ist somit umweltschonend.