Returning the MRS-1044 to the factory
default condition
The supplied CD-ROM contains complete data about the factory default
settings of the MRS-1044. Using the application program "Factory
Recovery Tool", you can automatically copy these data to the hard disk of
the MRS-1044, thereby restoring the MRS-1044 to the factory default
condition.
Formatting the hard disk of the MRS-1044
Before copying data to the hard disk of the MRS-1044, the hard disk must
be formatted (initialized).
• Use this function with care. When you execute the formatting
NOTE
process, all contents of the MRS-1044 will be lost.
• Perform formatting of the hard disk of the MRS-1044 only
according to the following steps.
• Never format the hard disk of the MRS-1044 using regular
Windows commands. If the hard disk was formatted by the
computer as a regular hard disk, it cannot be used by the MRS-
1044.
1.
Verify that the MRS-1044 is turned off. While holding down
the [CLEAR] key of the MRS-1044, press the [POWER]
switch on the rear panel to turn the unit on.
2.
Verify that "ROM UTY MRS-1044" is shown on the display
of the MRS-1044, and press the [MARK] key.
After a while, the indication "Format? ENTER" appears on the
display of the MRS-1044.
3.
Press the [ENTER] key to execute the formatting process.
Formatting of the internal hard disk of the MRS-1044 begins. When
formatting is complete, the indication "Format Done" appears on the
display of the MRS-1044.
To abort the formatting, press the [POWER] switch instead of the
[ENTER] key, and then press the [ENTER] key or the [EXIT] key.
Formatting is canceled and the MRS-1044 is turned off.
24
ZOOM UIB-01
4.
When formatting is complete, press the [POWER] switch of
the MRS-1044 and then the [ENTER] key.
Power to the MRS-1044 is turned off.
Using the Factory Recovery Tool
The supplied Factory Recovery Tool application program can be used to
copy the factory default setting data to the hard disk of the MRS-1044.
1.
Start up the MRS-1044 with formatted hard disk in USB
mode, and connect it to the computer with a USB cable.
Verify that the online state is established.
2.
Insert the supplied CD-ROM into the CD-ROM drive of the
computer, and double-click on "My Computer".
3.
Double-click on the "UIB_01_CD" icon in "My Computer".
4.
Double-click on the "FactRcvr" icon.
The Factory Recovery Tool starts up.
5.
Open the [FACTORY CD DRIVE] pull-down menu, and
specify the CD-ROM drive letter.
6.
Open the [MRS-1044 DRIVE] pull-down menu, and specify
the drive letter of the MRS-1044 recognized as a local hard
disk.
7.
Click on the [EXECUTE] button at the right of the screen.
The data copy process starts. The copy progress is indicated by the
bar under the screen.
8.
When the copy process is completed, click on the [CLOSE]
box.
The Factory Recovery Tool terminates.
• The copy process takes about 10 minutes. During this interval, you
NOTE
can abort the process by clicking on the [ABORT] button shown on
the screen.
• While the data are being copied, do not operate any of the keys
and switches of the MRS-1044.