Structure Of The Global Data Area Of The Data Unit Fs_Var - Siemens Simotion A4027118-A0414 User Manual

Flying saw v1.4
Table of Contents

Advertisement

Flying Saw with SIMOTION
Parameter
Input/output parameter (IN/OUT)
UsersInterface
ErrorInterface
InternalData
SyncPos
Management
TimeCalc
Output parameter (OUT)
Done
Busy
Error
Cut
EndSyncPos
Reached
OnTheSpotCut
Possible
OnTheSpotCut
Done
SyncNotPossible
ErrorID
State
6.3.3

Structure of the global data area of the data unit FS_Var

The interconnection and links with the technology objects required and the
physical reference quantities and control information are saved in the user
interface of the instance data area.
The parameters saved here are generally not changed during fault-free
operation of the "flying saw".
V 1.4
Section C: Integrating the core "flying saw" functions
Program environment and interfaces
Data type
Initial value
STRUCT
STRUCT
STRUCT
STRUCT
STRUCT
BOOL
False
BOOL
False
BOOL
False
BOOL
False
BOOL
False
BOOL
False
BOOL
False
BOOL
False
WORD
0
INT
0
Release 06/06/08
A4027118-A0414
Description
User interface
ErrorID of the technology
functions
Internal data of the sequence
control
Data of the synchronous
position management
Time calculation data
Selected mode has been
activated.
Mode changeover is active.
Indicates faults/errors within
the FBs and at the cross-cutter
axes.
The flying saw moves in
synchronism with the material
web – cutting can start.
Alarm, if the flying saw
passes/exceeds the upper limit
value of the synchronous range
when in the automatic mode
The flying saw is in its starting
position and an immediate cut
is possible
The immediate cut was carried-
out
The last synchronization
operation could not be
executed with the secondary
conditions/constraints present.
Fault code
Actual operating mode
68/107