Identify Device Command - Seagate Momentus 5400.2 Blade Server Product Manual

Blade server drives
Table of Contents

Advertisement

4.1.2

Identify Device command

The Identify Device command (command code EC
power up. The data is organized as a single 512-byte block of data, whose contents are shown in Table 6 on
page 22. All reserved bits or words should be set to zero. Parameters listed with an "x" are drive-specific or
vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings.
The following commands contain drive-specific features that may not be included in the Draft ATA-6 Standard.
Word
Description
0
Configuration information:
• Bit 15: 0 = ATA; 1 = ATAPI
• Bit 7: removable media
• Bit 6: removable controller
• Bit 0: reserved
1
Number of logical cylinders
2
ATA-reserved
3
Number of logical heads
4
Retired
5
Retired
6
Number of logical sectors per logical track: 63
7–9
Retired
10–19
Serial number: (20 ASCII characters, 0000
20
Retired
21
Retired
22
Obsolete
23–26
Firmware revision
(8 ASCII character string, padded with blanks to end of string)
27–46
Drive model number (40 ASCII characters, padded with blanks
to end of string)
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple and
Write multiple (16)
48
Reserved
49
Standard Standby timer, IORDY supported and may be disabled
50
ATA-reserved
51
PIO data-transfer cycle timing mode
52
Retired
53
Words 54–58, 64–70 and 88 are valid
54
Number of current logical cylinders
55
Number of current logical heads
56
Number of current logical sectors per logical track
57–58
Current capacity in sectors
Momentus 5400.2 Blade Server Product Manual, Rev. B
) transfers information about the drive to the host following
H
Value
0C5A
16,383
0000
16
0000
0000
003F
0000
= none)
ASCII
H
0000
0400
0000
x.xx
ST9120821AB
ST9100824AB
ST98823AB
ST96812AB
ST94813AB
8010
0000
2F00
0000
0200
0200
0007
xxxx
xxxx
xxxx
xxxx
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
25