15.

TROUBLESHOOTING

PROBLEM
No reading on the
ammeter.
Ammeter reading
stays high.
Ammeter reads less
than selected charge
rate when charging a
discharged battery.
The charger is
making an audible
clicking sound.
POSSIBLE CAUSE
Charger is not plugged in.
No power at the receptacle.
Clips are not making a good
connection to the battery.
Connections are reversed.
Battery is defective (will not
accept a charge).
2 amp charge rate is being used.
Battery is severely discharged.
Wrong battery voltage.
Extension cord is too long or wire
gauge is too small.
Weak cell or sulfated plate in
battery.
Battery is only partially
discharged.
Circuit breaker is cycling.
Battery is defective.
Shorted battery cables or clips.
Severely discharged battery, but
otherwise it is a good battery.
Reverse connections at battery.
Plug the charger into an
A.C. outlet.
Check for open fuse or circuit
breaker supplying A.C. outlet.
Check for poor connection to
battery and frame. Make sure
connection points are clean.
Rock clips back and forth for a
better connection.
Unplug the charger and reverse
the clips.
Have battery checked.
Ammeter may show no activity at
the 2A charge rate.
Continue charging battery for two
more hours. If problem continues
have the battery checked.
Verify the voltage settings or
output ratings on the charger
are correct.
Use a shorter or heavier gauge
extension cord.
A sulfated battery will eventually
take a normal charge if left
connected. If the battery will not
take a charge, have it checked.
Continue to charge the battery.
The settings may be wrong.
Check the charger settings.
Have the battery checked.
Circuit breaker cycles when
current draw is too high. Check
for shorted cables or clips and
replace if necessary.
The battery may not want to
accept a charge due to a run-
down state. Allow charging to
continue until battery has a
chance to recover sufficiently to
take a charge. If more than 20
minutes, stop charging and have
the battery checked.
Shut the charger off and correct
the lead connections.