Flexible Couplings & Connectors; Manual Pilot Valve; Testing And Adjustments - U.S. Range “REGAL” SERIES Installation And Operation Manual

Stock pot stoves
Hide thumbs Also See for U.S. Range “REGAL” SERIES:
Table of Contents

Advertisement

INSTALLATION Continued
Flexible Couplings & Connectors.
If the unit is to be installed with flexible couplings and/or
quick-disconnect fittings, for an appliance equipped with
casters, the installation shall be made with a connector that
complies withthe Standard for Connectors for Movable Gas
Appliances, ANSI Z21.69 /CSA 6.16, and a quick-disconnect
device that complies with the Standard for Quick-Disconnect
Devices for Use With Gas Fuel, ANSI Z21.41 / CSA 6.9, and
adequate means must be provided to limit the movement
of the appliance without depending on the connector and
the quick-disconnect device or its associated piping to limit
the appliance movement and the location(s) where the
restraining means may be attached to the appliance shall be
specified.
Further, if the unit is to be installed on a non-combustible
surface that is equipped with casters, means must be
provided to limit the movement of the unit on this surface.
Page 6

Manual Pilot Valve

Both burners of the ring burner pair are lighted from one
constant-burning pilot. These should be manually lighted
immediately after the gas is turned on and the system is
checked for leaks. An adjustment screw for each pilot is
located on the gas manifold and can be accessed through
openings in the valve panel between the valve knobs.

Testing and Adjustments

Check all gas connections for leaks using a soapy solution
before lighting any pilots. DO NOT USE OPEN FLAME
TO CHECK FOR LEAKS! Putting open flame beside a new
connection is not only dangerous, but will often miss small
leaks that a soapy solution would find.
All U.S. Range appliances are adjusted and tested before
leaving the factory, effectively matching them to sea
level conditions. Adjustments and calibrations to assure
proper operation may be necessary on installation to meet
local conditions, low gas pressure, differences in altitude;
variations in gas characteristics, to correct possible problems
caused by rough handling or vibration during shipment, and
are to be performed only by qualified service personnel.
These adjustments are the responsibility of the customer,
installer and/or dealer and are not covered by the U.S. Range
warranty.