OPERATION Continued
Shutdown
1. Turn all valves to the off position.
If the unit is to be shut down for an extended time, close the
in-line gas valve.

Thermostatically Controlled Griddles

1. Light the pilots at the front right side of the burner via
a long match or tape through the opening in the valve
panel.
2. Set the thermostat to maximum one at a time. The burner
should have a 5/16" high stable flame.
CAUTION: Do not allow the griddle to heat for longer than
one minute. The griddle must be seasoned before use.
(Refer to the Passage Entitled "Griddle Seasoning").
Shut Down
1 Turn all thermostat valves to the OFF position.
2 If the unit is to be shut down for an extended time, close
the in-line gas valve.

Valve Controlled Griddles

1. Light the pilot at the front right side of the burner via a
long match or taper through the opening in the valve
panel.
2. Turn the burners on by rotating them to the "ON"
position. The burners should have a 1/2" to 5/8" stable
blue flame.
CAUTION: Do not allow the griddle to heat for longer than
one minute. The griddle must be seasoned before use.
(Refer to the Passage Entitled "Griddle Seasoning").
Shut Down
1. Turn all valves to the OFF position.
2. If the unit is to be shut down for an extended time, close
the in-line gas valve.
Part # 3052000 (09/16/09)

Oven (Standard)

OVEN
THERMOSTAT
RED
RESET
BUTTON
Lighting
1. Remove Oven bottom.
2. Depress and hold reset button (red) located through the
access hole on the front control panel to the left of the
oven door (When facing the unit front.) While lighting the
oven pilot, continue to depress the reset button for 60
seconds. Release button. If pilot does not stay lit, repeat
this procedure after 5 minutes.
3. Turn oven valve knob to the "ON" position.
4. Rotate oven thermostat dial to the desired setting.
Shut Down
1. Turn oven valve and thermostats to, the off position.
2. If range is to be shut down for an extended period of
time, close the in line gas valve.
Relighting
1. Shut all gas valves off.
2. Wait 5 minutes.
3. Repeat lighting instructions in lighting above.
SERIAL PLATE