Figure 9. Current Profile: Note 3 amp figure is incorrect; use 4.3 amp as specified above.
5.3

Power On-Off Sequences

The Monitor will automatically return to normal operation upon resumption of power after a
power loss.

6.0 Display Performance

6.1

Display Luminance

The display provides one level of luminance used for both daylight and night viewing.
Minimum white-light luminance at the screen center of the Monitor face is 1500 cd/m
a darkened room environment with ambient light conditions less than 10 LUX [1fC] incident
illumination and at room temperature. Reference: MIL-L-85762A (3.10.2.2.3). Luminance
specification applies to the initial luminance, i.e. prior to additional operation in the end system.
6.2

Display Contrast

Display contrast is a relationship between luminance levels and the ability to perceive a
luminance difference. It is expressed as a ratio of ON white – luminance to OFF black background
luminance generated by the display.
Title: Product Specification: LC12 High-Bright Monitor
Document Number: 023-0284-01
1-msec (max)
Initial inrush current
Power Supply Limit
11-amp (max)
25-msec (max)
Stabilization
Luminance
? > 1,500cd/m
min
4.3 amp (max) steady -state
3-amp (max) steady-state
Time Scale: 10-msec / div
2
[467 fL]
25-amp
20-amp
15-amp
10-amp
5-amp
0-amp
2
[467 fL] in