Installation instructions
22
Power supply cord requirements for U.S.A (for electric models only)
Only a UL listed power-supply cord kit a suitable length for the installation and rated 120/240 V
min, 30 A and marked with use for clothes dryers shall be used.
This shall have ring terminals to connect to the dryer.
The UL-rated strain relief included with it shall be suitable for a 1 1/8" (28.5 mm) hole.
If your outlet looks like this
Connecting by direct wire
Power supply cable must match power supply (4-wire or 3-wire) and be:
Flexible armoured or non-metallic sheathed copper cable (with ground wire). All current-
carrying wires must be insulated.
10 gauge AWG solid copper wire (do not use aluminium wire).
Suitable length for the installation.
A UL approved strain relief must be used.
Grounding for a direct wired appliance
This appliance must be connected to a grounded metal permanent wiring system, or an
equipment grounding conductor must be run with the circuit conductors and connected to the
equipment-grounding terminal on the appliance.
Fig.20 UL listed power-supply cord
3 wire
4 wire
Choose this power supply cord