120V PLUG-IN CARBON MONOXIDE ALARM
WITH SILENCE FEATURE
~
120V AC
,
60 Hz, 0.09A
Printed in Mexico M08-0152-002 S 07/07
IMPORTANT!
PLEASE READ CAREFULLY AND SAVE.
This user's manual contains important information about your Carbon
Monoxide (CO) Alarm's operation. If you are installing this CO Alarm
for use by others, you must leave this manual-or a copy of it-with
the end user.

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
How Your CO Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Understanding Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Where to Install CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where CO Alarms Should NOT Be Installed . . . . . . . . . . . . . . . .2
How to Install Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If Your CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If the Alarm Signal Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Testing and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . .4
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Finding the Source of CO After an Alarm . . . . . . . . . . . . . . . . . .4
Potential Sources Of CO In The Home . . . . . . . . . . . . . . . . . . . .4
How Can I Protect My Family? . . . . . . . . . . . . . . . . . . . . . . . . . .4
Regulatory Information for CO Alarms . . . . . . . . . . . . . . . . . . . . . . . 5
General Limitations Of CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
© 2007 BRK Brands, Inc., a Jarden Corporation company (NYSE: JAH)
3901 Liberty Street Road, Aurora, IL 60504-8122
All rights reserved.
Consumer Affairs: (800) 323-9005 • www.firstalert.com
USER'S MANUAL
Model
CO600
CONFORMS
TO UL 2034

INTRODUCTION

BASIC SAFETY INFORMATION

Dangers, Warnings, and Cautions alert you to important
operating instructions or to potentially hazardous situations.
Pay special attention to these items.
THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to
detect carbon monoxide from ANY source of combustion. It is
NOT designed to detect smoke, fire, or any other gas.
This CO Alarm is approved for use in single-family residences.
This CO Alarm will only indicate the presence of carbon
monoxide gas at the sensor. Carbon monoxide gas may be
present in other areas.
The Silence Feature is for your convenience only and will not
correct a CO problem. Always check your home for a potential
problem after any alarm. Failure to do so can result in injury or
death.
This CO Alarm should receive continuous 120VAC, 60 Hz, pure
sine wave electrical power. Do not use in an extension cord or
outlet controlled by a dimmer or switch.
NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer
to "If Your CO Alarm Sounds" for more information. Failure to
do so can result in injury or death.
Test the CO Alarm once a week. If the CO Alarm ever fails to
test correctly, have it replaced immediately! If the CO Alarm is
not working properly, it cannot alert you to a problem.
This product is intended for use in ordinary indoor locations of
family living units. It is not designed to measure CO levels in
compliance with Occupational Safety and Health Administration
(OSHA) commercial or industrial standards. Individuals with
medical conditions that may make them more sensitive to
carbon monoxide may consider using warning devices which
provide audible and visual signals for carbon monoxide con-
centrations under 30 ppm. For additional information on carbon
monoxide and your medical condition contact your physician.

HOW YOUR CO ALARM WORKS

GENERAL INFORMATION
Leave your CO Alarm plugged in year-round. CO problems can
occur any time during the year, and this Alarm can only alert you if
it is plugged in and receiving power.
When fully powered, the unit samples the air and takes a new reading
about every second. A microchip inside the unit stores each reading,
and remembers the levels of CO it has been exposed to over time.
The Alarm sounds when it has been exposed to a "critical" level of CO
(measured in parts per million or "ppm") within a specified time (meas-
ured in minutes). This CO Alarm features a permanently installed sensor,
an indicator light, and an 85 dB alarm horn. It also has a Silence
Feature to temporarily quiet the alarm horn.
MALFUNCTION WARNING
This unit performs daily self-diagnostic tests. If the Alarm malfunctions,
it should be replaced immediately.
THE COVER OF YOUR CO ALARM
3
1 Test/Silence Button
3 (Behind Cover) Alarm Horn: 85 dB audible alarm
for test, alarm, and unit malfunction warning
1
1
2
2 POWER/ALARM Light (Red)

Advertisement

loading

Summary of Contents for First Alert CO600

  • Page 1: Table Of Contents

    Do not use in an extension cord or outlet controlled by a dimmer or switch. • NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer to “If Your CO Alarm Sounds” for more information. Failure to do so can result in injury or death.
  • Page 2: Understanding Your Co Alarm

    WHAT YOU SEE AND HEAR DURING INSTALLATION WHEN YOU FIRST PLUG-IN THE CO ALARM: HORN: Silent POWER/ALARM LIGHT: Shines continuously UNDER NORMAL CONDITIONS (AC POWER): HORN: Silent POWER/ALARM LIGHT: Shines continuously WHEN YOU TEST THE CO ALARM: HORN: Sounds loudly - 4 beeps, pause, 4 beeps, pause POWER/ALARM LIGHT: Flashes rapidly WHAT YOU SEE AND HEAR UNDER DIFFERENT CONDITIONS: WHEN THE ELECTRICITY COMES BACK ON AFTER A POWER...
  • Page 3: How To Install Your Co Alarm

    HOW TO INSTALL YOUR CO ALARM Read “Where To Install Your CO Alarm” before starting. Before you start installation, find the pair of self-adhesive labels included with this CO Alarm. On each label write in the phone number of your emergency responder (like 911) and a qualified appliance tech- nician.
  • Page 4: What You Need To Know About Co

    WHAT IS CO? CO is an invisible, odorless, tasteless gas produced when fossil fuels do not burn completely, or are exposed to heat (usually fire). Electrical appliances typically do not produce CO. These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene, and propane.
  • Page 5: Regulatory Information For Co Alarms

    REGULATORY INFORMATION FOR CO ALARMS WHAT LEVELS OF CO CAUSE AN ALARM? Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms to sound when exposed to levels of CO and exposure times as described below. CO levels are measured in parts per million (ppm) of CO over time (in minutes).
  • Page 6: Troubleshooting Guide

    If you have any questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005. BRK Brands, Inc. ("BRK") the maker of First Alert will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period.