4. PERFORMANCE DATA

[a] KM-900MAH
APPROXIMATE ICE
PRODUCTION PER 24 HR.
lbs./day kg./day
APPROXIMATE ELECTRIC
CONSUMPTION
watts
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
3
gal./day
m
/day
FREEZING CYCLE TIME
min.
HARVEST CYCLE TIME
min.
HEAD PRESSURE
2
PSIG
kg/cm
G
SUCTION PRESSURE
2
PSIG
kg/cm
G
TOTAL HEAT OF REJECTION FROM CONDENSER
Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used for
reference only.
We reserve the right to make changes in specifications and design without prior notice.
AMBIENT TEMP.
(ºF/ºC)
70/21
838
80/27
812
90/32
804
100/38
795
70/21
80/27
90/32
100/38
70/21
472
80/27
421
90/32
410
100/38
405
70/21
80/27
90/32
100/38
70/21
80/27
90/32
100/38
70/21
245
80/27
262
90/32
267
100/38
272
70/21
33
80/27
35
90/32
36
100/38
37
43
WATER TEMP. (ºF/ºC)
50/10
70/21
380
804
368
759
365
721
361
710
1783
1836
1824
1907
1860
1965
1900
1967
1.79
405
1.59
317
1.55
244
1.53
235
22
21
22
24
22
26
23
27
4.5
3.9
4.1
3.1
4.0
2.5
3.9
2.4
17.2
267
18.4
296
18.8
320
19.1
327
2.3
36
2.5
39
2.5
42
2.6
43
14800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
90/32
365
759
344
344
715
324
327
676
306
322
634
288
1860
1920
1973
1980
1.53
356
1.35
1.20
292
1.10
0.92
208
0.79
0.89
174
0.66
25
27
29
31
3.5
3.0
2.2
2.0
18.8
296
20.8
20.8
324
22.7
22.5
349
24.5
23.0
375
26.4
2.5
40
2.8
2.7
43
3.0
3.0
46
3.2
3.0
50
3.5