3

LINE VOLTAGE ADJUSTMENTS

A voltage selection is provided inside the amplifier.
If your line voltage is not adapted to the voltage indicated on the serial plate of the
amplifier, please consult your local GOLDMUND dealer for internal adjustment.
ATTENTION
ATTENTION
ATTENTION
ATTENTION
On the 220V configuration, the GOLDMUND TELOS 350 amplifier will function properly for
main line voltage between 190V and 245V. On the 110V configuration, the main line must
deliver between 95 and 125V. If your main line is usually out of these tolerances, please
consult your GOLDMUND dealer.
Please check the value of the main line fuse. This fuse is located on the back panel of the
amplifier, above the power cord receptacles.
Use a 16A delayed fuse.