    4030B Active Loudspeaker General Connections The bi-amplified Genelec 4030B is an extremely Before connecting up, ensure that the loudspeakers compact two way active loudspeaker designed for and the signal source have been switched off. The fixed installations. As an active loudspeaker, it con-...
  • Page 3: Level Control

    Autostart And Remote Control Setting the tone controls The 4030B is equipped with an Autostart function, The frequency response of the Genelec 4030B which automatically turns the amplifier to Standby can be adjusted to match the acoustic environ- mode if an input signal has not been detected for ment by setting the tone control switches on the approximately 1 hour.
  • Page 4: Mounting Considerations

    Loudspeaker Mounting Position Treble Tilt Bass Tilt Bass Roll-Off Flat anechoic response Free standing in a damped room Free standing in a reverberant room -2 dB Near field or desktop -4 dB Near to a wall -6 dB Table 1: Suggested tone control settings for differing acoustical environments Mounting considerations Treble Tilt The Treble Tilt control (switch 1) attenuates the treble...
  • Page 5: Mounting Options

    Mounting options which may cause per manent hear ing The Genelec 4030B offers several mounting op- damage. tions: On the base of the loudspeaker is a 3/8” • Free flow of air behind the loudspeaker is UNC threaded hole compatible with a standard necessary to maintain sufficient cooling.
  • Page 6 Genelec Oy 4030 (dBr) vs freq (Hz) 7 Nov 2012 Figure 4. The curves show the effect of the “Bass Tilt”, “Treble Tilt” and “Bass Roll-Off” controls on the free field response of the 4030B TREBLE TILT BASS TILT BASS ROLL-OFF...
  • Page 7: System Specifications

    SYSTEM SPECIFICATIONS CROSSOVER SECTION Input connector: Balanced 10 kOhm Lower cut-off frequency, –3 dB: < 55 Hz _____________________________________________ _____________________________________________ Upper cut-off frequency, –3 dB: > 21 kHz Input level for 100 dB SPL output at 1 m: _____________________________________________ -6 dBu at level control max Free field frequency response of system: _____________________________________________ 58 Hz –...
  • Page 8 Jianwai SOHO, Tower 12, Room 2605 D-1504, Chaoyang District Beijing 100022, China Phone +86 10 8580 2180 Fax +86 10 8580 2181 Email genelec.china@genelec.com www.genelec.com Genelec Document D0091R001a Copyright Genelec Oy 1.2013. All data subject to change without prior notice...