a poor location for sensing temperature
or if you want to install the thermostat
in a separate room to prevent tamper-
ing. Alter installing and connecting the
remote sensor(s) to the thermostat, the
installer can enable each remote indoor
temperature sensor (A, B, and!or C).
When operating with remote sensor(s),
the thermostat will calculate an
average of the sensed temperatures in
all enabled sensor locations (A, B, C
and/or L), then display the average
temperature as the room temperature.
The temperature at each remote sensor
can be displayed by pressing the light
button twice within one second, with
the thermostat in program run or hold
mode. Temperatures at the outdoor and
indoor remote sensors will be displayed
with subsequent presses of the light
button in the following order (if
connected): outdoor sensor, sensor L,
A,B, C.
You can also assign
each sensor
different
priorities
during different
program
periods.
This allows the
system
to maintain
a comfortable
environment
by giving higher priority
to occupied
locations.
At the same
time, efficient
system
operation
is
enhanced
by giving lower priority
to
unoccupied
locations.
EXAMPLE:
Your home
has bedrooms
on the upper level and a guest bedroom
on the main level, along
with the living
room, kitchen,
etc. The thermostat
(sensor
L) is located
in the hall on the
main level. Remote
sensors
are located
on the upper level (sensor A) and the
guest bedroom
(sensor
B). The lower
level would
be occupied
in the DAY
and EVE periods.
The upper level
would
be occupied
in the NHT and
MOR periods.
With no guest in the
guest bedroom,
the sensors
could be
programmed
as follows:
19
SENSOR
L
A
B
MOR
AVG
HI
LO
DAY
Hi
AVG
LO
EVE
HI
AVG
LO
NHT
AVG
Hi
LO
In the MOR and NHT periods,
the
sensor on the upper level (sensor
A)
has more priority
than the lower level
(sensor
L), so the system will operate
to keep the temperature
at the set point
in the upper level. In the DAY and
EVE peroids,
the lower level has the
higher priority,
so the system
will
operate
to keep teh temperature
at the
set point on that level. The sensor in
the guest bedroom
has the lower
priority
of the sensors.
If there is a
guest, the sensor in that room (sensor
B) should be changed
to AVG or HI tbr
periods
when that room will be used.,