Current Measurements - Fluke 183 User Manual

True rms multimeters
Table of Contents

Advertisement

This calibrates the meter for the operating environment.
display. If you hear an error beep, the offset is greater than 5 C. You can
repeat this calibration at any time. To undo this calibration, return the meter to
factory settings by pressing both the yellow (shift) button and
powering up the meter (see Table 3. Power-up Options).
To insure accuracy of temperature measurements, you should follow this
procedure when using other K-type thermocouple probes with the 183/185
DMMs because accuracy specifications vary in different types of probes.
Observe proper polarity on the probe adapter and do not calibrate
the offset immediately following high amperage measurements.

Current Measurements

Measurement
True RMS AC
Amps
DC Amps
(default)
Amps AC DC
dual display
Amps AC+DC
1
total RMS
4-20 mA
2
current %
(185 only)
Irms
IAC
1
2
4-20 mA measurement is used in process loop calibration. % = (measured
current – 4 mA)/16 mA
Softkey
AC
DC
AC
DC or
AC+DC
(press to
toggle)
20 mA
2
2
IDC
True RMS Digital Multimeters
Note
Connect leads
Current
Load
source
ahr17f.eps
Operating Basics
shows in the upper
while
MIN MAX
Main
Upper
Display
Display
AC
Hz
DC
--
DC
AC
AC+DC
Hz
DC
%
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

185

Table of Contents