nstaHation Instructions
Ifnew dryer isinstalled intoan existingexhaust system you
must make sure:
The exhaust system meets all local, state, and national codes.
That flexible
plastic duct is not used.
Inspect and clean all lint buildupfrom
inside the existing duct.
The duct is not kinked or crushed.
The exhaust hood damper opens and closes freely.
The static pressure in any exhaust system must not exceed 0.83 inches of water column, or be less than 0.
This can be measured with the dryer running with a manometer at the point where the exhaust duct connects
to the dryer. A no-heat setting should be used. The dryer tum bier should be em pry and the lint filter clean.
iMPORTANT TO iNSTALLER
Please read the following
instructions
carefully
before installing the dryecThese
instructions
should be
kept for future reference.
REMOVE THE DOOR FROM ALL DISCARDED APPLIANCES TO AVOID THE DANGER OF A
CHILD SUFFOCATING.
LOCATION CONSIDERATIONS
The dryer should be located where there is enough space in front for loading the dryer, and enough
space behind for the exhaust system.This
dryer is factory-ready
for rear exhaust.To
exhaust out the
bottom
or the left, use the accessory exhaust kit. Instructions
are included
with the kit. It's important
to make sure the room has enough fresh air.The dryer must be located where there is no airflow
obstruction.
On gas dryers, adequate clearance as noted on the data plate must be maintained
to ensure adequate
air for combustion
and proper dryer operation.
THE DRYER MUST NOT BE INSTALLED OR STORED IN AN AREA WHERE ITWlLL BE EXPOSEDTO WATER
AND/OR WEATHER.THE DRYER AREA ISTO BE KEPT CLEAR OF COMBUSTIBLE MATERIALS, GASOLINE,
AND OTHER FLAMMABLE VAPORS AND LIQUIDS. A DRYER PRODUCES COMBUSTIBLE LINT.THE AREA
AROUNDTHE DRYER SHOULD BE KEPT LINT FREE.
ALCOVE OR CLOSET iNSTALLATiON
,_WARNING
-
The dryer must be exhausted
to the outside to reduce the risk of fire when
installed in an alcove or closet.
No other fuel-burning
appliance
should be installed in the same closet as the dryen
WARNING:To reduce the risk of fire, this dryer MUST BE EXHAUSTEDTOTHE
OUTDOORS.
See EXHAUST INFORMATION section.
Minimum
clearances between
the dryer and adjacent
walls or other surfaces are: 2"in front,
17" on top, 1"on either side, and 2.375"in the back.
Closet front must have two unobstructed
air openings
for a combined
minimum
total area of
2
72in
with 3" minimum
clearance on the top and bottom. A Iouvered door with equivalent
space
clearance is acceptable.
SAMSUNG DryerOwner's Manual A-3