Ducting Requirements - Samsung DV3C6BGW/XAA Owner's Manual

Gas and electric dryer
Hide thumbs Also See for DV3C6BGW/XAA:
Table of Contents

Advertisement

nstaHation
nstructions
DUCTiNG REQUIREMENTS
Use a 4-inch (10.2 cm) diameter
rigid aluminum
or rigid galvanized
steel duct.
Do not use a smaller duct.
Ducts larger than 4 inches (10.2 cm) in diameter
can result in increased lint accumulation.
Lint accumulation
should be cleaned regularly.
If a flexible
metal duct must be used, use the type with a stiff sheet metal wall. Do not use a flexible
duct with a thin foil wall. Serious blockage can result if the flexible
metal duct is bent too sharply.
Never install any type of flexible
duct in walls, ceilings, or other concealed
spaces.
Keep exhaust duct as straight and short as possible.
Secure joints with duct tape. Do not use screws.
DO NOT EXHAUST DRYER INTO ANYWALL, CEILING, CRAWL SPACE, OR CONCEALED SPACE OF A
BUILDING, GAS VENT, OR ANY OTHER COMMON DUCT OR CHIMNEY.
THIS COULD CREATE A FIRE HAZARD FROM LINT EXPELLED BYTHE DRYER.
Plastic flexible
duct can kink, sag, be punctured,
reduce airflow, extend drying times, and affect dryer
operation.
Exhaust systems longer than recommended
can extend drying times, affect machine
operation,
and
may collect lint.
The exhaust duct should end with an exhaust hood with a swing-out
damper
to prevent back drafts
and entry of wildlife. Never use an exhaust hood with a magnetic
damper.
The hood should have at least 12 inches (305 cm) of clearance between
the bottom
of the hood and
the ground
or other obstruction.The
hood opening
should point down.
Never install a screen over the exhaust outlet.
To avoid lint buildup,
do not exhaust the dryer directly into a window
well. Do not exhaust under a
house or porch.
If exhaust ductwork
must run through
an unheated
area, the duct should be insulated and slope
slightly down towards the exhaust hood to reduce condensation
and lint buildup.
Inspect and clean the interior of the exhaust system at least once a year. Unplug
the power cord
before cleaning.
Check frequently
to be sure the exhaust hood damper
opens and closes freely.
Check once per month, and clean at least one time per year. Note: If clothes are not getting dry,
then check ducting
for obstructions.
ELECTRIC AND GAS DRYER
Weather Hood Type
Recommended
Use only for short-run
installation
No. of 90°
elbows
Rigid
Metallic Flexible _
Rigid
Metallic Flexible _
0
24.4 m (80 ft.)
12.4 m (41 ft.)
22.6 m (74 ft.)
10.1 m (33 ft.)
1
20.7 m (68 ft.)
11.2 m (37 ft.)
18.9 m(62 ft.)
8.8 m (29 ft.)
2
17.4 m (57 ft.)
10.1 m (33 ft.)
15.5 m(51 ft.)
7.6 m (25 ft.)
3
14.3m (47 ft.)
9.0 m (29 ft.)
12.5 m(41 ft.)
6.5 m (21 ft.)
Do not use non-metallic flexible duct.
A-2 SAMSUNG Dryer Owner's Manual

Hide quick links:

Advertisement

Table of Contents
loading