Care and Cleaning
The surface burner heads are removable.
The cap
portion of the head is porcelain
and the port area
is aluminum.
Wash the burner heads in the sink
with mild detergent
and a plastic scrubber. For
stubborn
stains, clean with Cooktop
Cleaning
Creme (Part #20000001)**.
I_ Check to be sure all ports are open. To open
clogged
ports, insert a straight pin directly into each
port. Do not enlarge or distort the port.
The aluminum
burner base is not removeable.
To
clean, wipe with a damp cloth.
When replacing
the burner heads, carefully
align the
tab on the burner base with the indentation
in the
head.
The two pins will fit in the slots when the tab
is aligned with the indentation.
BURNER
HEAD
Port Area
Slots Alic
BURNER
BASE
Indentation
Ignitor
NOTE:
When burner
heads are removed for cleaning,
do not spill liquids through
the holes
in the burner
base.
* Brand names ace trademarks of the respective manufacturers.
** To order call 1-800-688-8408.
Be[ore
You Call
For Service
Check the following list to be sure a service call is really necessary.
If surface burner fails to light:
I, check to be sure unit is properly connected to power supply.
check for a blown fuse or a tripped main circuit breaker.
check to be sure burner is correctly rated for your type of gas.
i, check to be sure burner ports or ignition ports are not clogged.
check to be sure ignitor is dry and clicking. Burner will not light
if ignitor is damaged, soiled or wet. if ignitor doesn't click, turn
control knob OFF.
check to be sure the burner head is correctly seated on the burner
base.
If the flame is uneven:
burner ports may be clogged.
make sure the burner head is correctly seated on the burner base.
If surface burner flame lifts off the ports:
contact an authorized Jenn-Air Servicer.
If surface burner flame is yellow in color:
contact an authorized Jenn-Air Servicer.
some yellow tips on the flames are acceptable when
using LP gas.
If ventilation system is not capturing smoke efficiently:
check on cross ventilation in room or make up air.
outside wallcap may be trapped shut.
cooktop may beimproperly installed (see p. 3); check installation
instructions.
check filter installation (see p. 5).
m mJENN-AIR
403 WEST
FOURTH
STREET
NORTH
• NEWTON,
IA 50208
A!IO/00
Part No. 811 lP422-60