GE JGP640 Use And Care & Installation Manual page 15

Gas downdraft cooktop
Hide thumbs Also See for JGP640:
Table of Contents

Advertisement

STEP 7 (continued)
INSTALLINGTHE COOKTOP
NOTE:
If the cooktop
is installed
in a 36" base
cabinet,
the mounting
brackets
cannot
be used
because
of the interference
with the sides of the
cabinet.
In this case, the cooktop
can be secured
to the sides of the cabinet
using
angle
brackets
(not supplied).
Remove
one screw
at the bottom
of the cooktop
body, on each side, then replace
to hold the bracket
to the cooktop.
Then
secure
the brackets
to the cabinet
sides with the screws
provided.
Connect
the 9-pin plastic plug from the downdraft
unit to the 9-pin plastic
socket
situated
adjacent
to the power
cord on the cooktop.
Secure
the
metal cover in position
over the connection.
9-Pin Socket
Service Plate
Electrical
Supply Cord 9-Pinplug
"_
_--_-_1;
Metal Cover "_-!_
Layout
of Service
Panel
Pressure
Test Point
,Pressure
Regulator
STEP8
GASCONNECTION
Install
the supplied
pressure
regulator
and nipple
in the gas
line as close
to the cooktop
inlet
as possible,
making
allowances
for
ventilation
ducting
as necessary.
Make
sure the regulator
is
installed
in the right direction.
Install
a manual
shut-off
valve in
the gas line in an easily accessible
location,
as close to the pipe stub
as possible,
making
allowances
for
the ventilation
ducting.
Be sure
you know how and where
to shut
off the gas supply
to the cooktop.
NOTE:
Instead
of using
solid
piping to connect
to pressure
regulator,
an approved
flexible
metal appliance
connector
may be
used between
the pipe stub and
shut-off
and the pressure
regulator,
if local codes
permit.
Appropriate
flare union
adapters
are required
at
each end of the flexible
connector.
Turn on the gas; check for leaks using a liquid leak
detector at all joints in the system (the pressure
test nipple is adjacent to the gas inlet pipe on the
rear right hand side of the cooktop bottom).
CAUTION:
DO NOT USE A FLAME TO
CHECK FOR GAS LEAKS.
IMPORTANT--
Disconnect
the cooktop
and
the individual
shut-off
valve from the gas supply
piping system
during
any pressure
testing
of that
system
at test pressures
greater
than 1/2 psig.
Isolate
the cooktop
from the gas supply
piping
system
by dosing
the individual
manual
shut-off
valve to the cooktop
during
any pressure
testing
of the gas supply piping
system
at test pressures
equal to or less than 1/2 psig.
STEP9
INSTALLTHE DUCTWORK
Use minimum 26 gauge galvanized or 24 gauge
aluminum duct in 6" round or 31/4" x 10" size, or
a combination
of both. PVC duct should be used
if installing under a poured concrete slab. DO
NOT use flexible ducting.
Always
use an
appropriate
roof
or wall cap with
damper.
Laundry
type wall caps
should
never
be
used. Use the
straightest
duct
run possible.
For satisfactory
performance
the duct run should
not exceed
75 ft. or its equivalent
length
if bends
or other
various
fittings
are used.
Refer to table
of
equivalent
lengths
for various
duct configurations.
Install
ductwork
so that the piece of duct nearest
the downdraft
unit slots INTO
the next piece of
duct. Secure
all joints with self tapping
screws
and apply duct tape around
the joint to ensure
an
airtight
seal.
(continued next page)