GE GSH25JFPACC Owner's Manual And Installation Instructions page 27

Side by side refrigerators models 20, 22 and 25
Table of Contents

Advertisement

Available languages

Available languages

Performance Data Sheet
SmartWater FiltrationSystem
GWF/ HWF Cartridge
Thissystemhas been tested accordingto NSF/ANS142/53for reductionof the substanceslisted below.
Theconcentrationof the indicatedsubstancesin water entering the systemwas reducedto a concentration
less than or equal to the permissible limit for water leaving the system,as specified in NSF/ANS142/53.*
(100%safety factors built in for unmetered usage)
Pm'ameter
USEPA
MCL
Chlodne
T&O
Par ticulatc**
Standard No. 42: Aesthetic Effects
Influent
Effluent
ChallengeConcenwation
Average
Maximum
2.0 mg/L + 10%
0.02 ppm
0.05 ppm
at least 10,000
partides/mL
3,978
7,800
% Reduction
Average
Mi_fimmn
98.90%
97.37%
98.00%
911.10%
Min. Required
Reduction
>50%
>85%
Pl_Reanleter
'lhrhidi W
Lead at pH 11.5
Lead at pH 8.5
Lindane
AtraTJne
2,4-D
,_bestos
USEPA
MCL
l NTU***
99.95%
Reduction
15 ppb
15 ppb
0.0002
ppm
0.003 ppm
0.100 ppm
99%
Standard
No. 53: Health
Effects
lnfluent
Challenge Concentration
11 + 1 NTU***
Minimum
50,000 L
0.15 rag/L+
10%
0.15 rag/L+
10%
0.002 mg/L+
10%
0.009 mg/L+
10%
0.210 mg/L+
10%
lfY to 1@ fit_rs/L;
libra* greawr than
10 micromete*_ in lenglh
Effluent
Average
Maximum
0.07 NTU
0.1 NTU
26
55
l pph
1 ppb
1.8 pph
4.3 ppb
0.00(_)5 ppm
0.00005
ppm
0.002 ppm
0.003
ppm
0.042 ppm
O.fY)O ppm
0.32 MFL/ml
1.2 MFL/ml
* Testedusinga flew rote of 0.5gpm; pressureof 60 psig;pH of Z5 _ 0.5; temp.of go° +_ Z5°C
** Measurementin Particles/ml.Particlesusedwere0.5-1microns
*** NTU=Nephelometric T urbidity units
% Reduction
Average
Minimum
99.71%
99.59%
99.97%
99.95%
99.37%
99.37%
98.8%
97.13%
91.93%
91.93%
76.19%
64.28%
84.89%
67.63%
99.95%
99.82%
Min. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.003 mg/L
0.07 mg/L
99%
Operating Specifications
• Capacity: certitied tbr up to 300 gallons (1135 l); up to six months for models without a replacement
fiher indicator light; up
to one year tbr models with a replacement
filter indicator light
• Pressure
requirement:
40-120 psi (2.8-8.2 bar), non-shock
• Temperature:
33-100°F
(0.6-38°C)
• Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance
Requirements
• Flush
new cartridge
at tull flow for 3 minutes
to purge
out trapped
ai_:
• Replace
cartridge
when
flow becomes
too slow.
Special Notices
• Installation
instructions,
parts
and smwice
availability,
and
standard
warranty
are included
with the product
when
shipped.
• This drinking
water
system
must
be maintained
according
to manufacturer's
instructions,
including
replacement
of filter
cartridges.
• Do not use with water that
is microbiologically
tmsati:
or of unknown
quality
without
adequate
disinfection
betore
or
after the system.
Systems
certified
1or cyst reduction
may be used on disinfected
,a_ater that
may contain
filterable
cysts.
• The
contaminants
or other
substances
removed
or reduced
by this water
treatment
system
are not necessarily
in your
water.
• Check
for compliance
with the state and local la,a_ and regulations.
• Note
that while the testing
was performed
under
standard
laboratory
conditions,
actual
pertormance
may vary. Systems
must
be installed
and
operated
in accordance
with manufacturer's
recommended
procedures
and guidelines.
8ysiem
'I_.,sted and
Certified
hy NSF international
against
ANSI/NSF
Standard
42 & 53 tor
the reduction
off
Standard
No. 42: Aesthetic
Effects
Chemical
Unit
'Ihste
and
Odor
Reduction
Chlorine
Reduction
Mechanical
Filtration
Unit
Particulate
Reduction,
Class
i
Stmadard
No.
53: Health
Effects
Chemical
Reduction
Unit
Lead
and
Atrazine
Reduction
Lindane
and
2,4-D Reduction
Mechanical
Filtration
Unit
Turbidily
Reduction
(;)<st and
,_besms
Reduction
Manutacmred
for:
General
Electric
Company,
Louisville,
KY 40225
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents