ATTENTION: Some Pelco-D / -P protocol domes and receivers require an address offset of -1. In
other words, the address assigned to the dome / receiver in the DVR camera menu must be 1 below
the address set in the dome / receiver itself! (i.e. DVR ID: 2, PTZ ID: 3)
2.4

Alarm Input / Output Installation

The EDR1640/1620/920 alarm inputs can be used for recording start or recording rate adjustment.
Furthermore, alarm reactions such as camera switching to monitors, buzzer, e-mail and network alarm
are available. An alarm output relay can be switched if required.
EDR920 provides 9 alarm inputs, EDR1640/1620 provides 16. All inputs are programmable NO/NC.
Inputs have to be switched through dry contacts.
The 4 output relays provide a dry NO/NC contact.
All settings are programmed in the ALARM menu.
Use either the 37-pin Sub-D plug or the included adaptor board for connection.
Pin assignment adaptor board
HOST
PIN #
NAME
PIN #
1
GND
21
2
ALMIN 1
22
3
ALMIN 2
23
4
ALMIN 3
24
5
ALMIN 4
25
6
ALMIN 5
26
7
GND
27
8
ALMIN 6
28
9
ALMIN 7
29
10
ALMIN 8
30
11
ALMIN 9
31
12
ALMIN 10
32
13
GND
33
14
ALMIN 11
34
15
ALMIN 12
35
16
ALMIN 13
36
17
ALMIN 14
37
18
ALMIN 15
38
19
ALMIN 16
39
20
GND
40
Pin assignment sub-d board
NAME
GND
ALM_NC1
ALM_NO1
ALM_COM1
ALM_NC2
ALM_NO2
ALM_COM2
GND
ALM_NC3
ALM_NO3
ALM_CO M3
ALM_NC4
ALM_NO4
ALM_COM4
GND
ALMRST
REC_IN
SPARE_IN
DISK_FULL
SPARE_OUT
18