PROBLEM
CORRECTION
Knocking Noise.
Remove and clean, or replace.
Decrease amount of air usage.
Compressor is not supplying
enough air to operate accessories.
Motor will not run.
Regulator knob has continuous air
leak.
Regulator will not shut off air out-
let.
CAUSE
Defective check valve.
Prolonged excessive use of air.
Compressor is not large enough
for air requirement.
Hole in hose.
Check valve restricted.
Air leaks.
Fuse blown, circuit breaker
tripped.
Extension cord is wrong length or
gauge.
Loose electrical connections.
Faulty motor.
Damaged regulator
Damaged regulator
Check the accessory air require-
ment.
If it is higher than the
SCFM or pressure supplied by
your air compressor, you need a
larger compressor.
Check and replace if required.
Remove and clean, or replace.
Tighten fittings.
Check fuse box for blown fuse
and replace as necessary.
Reset circuit breaker. Do not use a
fuse or circuit breaker with higher
rating than that specified for your
particular branch circuit.
Check for proper fuse. You should
use a time delay fuse.
Check for low voltage problem.
Check the extension cord.
Disconnect the other electrical
appliances from circuit or
operate the compressor
on its
own branch circuit.
Check the extension cord.
Check wiring connection
inside
terminal box.
Have checked by a Trained
Service Technician.
Replace
Replace