Troubleshooting Chart - Craftsman HYDROGLASS 390.252282 Owner's Manual

Hydroglass convertible deep well jet pump
Hide thumbs Also See for HYDROGLASS 390.252282:
Table of Contents

Advertisement

SYMlqOM
Motor will not rtax
TROUBLESHOOTING
CHART
_m6sm_ causes)
1.
2.
3.
4.
5.
Motor runs hot and
1.
overload
kicks off
2.
3.
Motor runs but no
1.
water
is delivered
2.
3.
4.
5.
6.
_Pm_pdoes-not
1.
deliver water
to full
capacity (ALso
2.
check
point
3
immediately above)
3.
Pump pumps water
1.
but does not shut
off
2.
3.
4.
5.
Pump cycles too
1.
frequently
2.
3.
4.
5.
6.
Air spurts from
1.
faucets
2.
3.
4.
Disconnect
switch
is off
Fuse is blown
Starting switch
is defective
Wires at motor are loose,
disconnected,
or wired incorrectly
Pressure
switch
contacts
are
dirty
Motor is wired
incorrectly
Voltage is too low
Pump cycles too frequently
Pump in new installation
did
not pick up prime through:
a.
Improper
priming
b. Air leaks
c. Leaking foot valve
Pump has lost prime through:
a. Air leaks
b. Water level below
suction
of pump
Jet or impeller
is plugged
Check valve or foot valve is stuck
in closed position
Pipes are frozen
Foot valve and/or
strainer
are
buried in sand or mud
Water level in well is lower than
estimated
Steel piping (if used) is corroded
or
limed, causing
excess
friction
Offset piping is too small in size
Pressure switch
is out of adjustment
or contacts
are "frozen"
Faucets
have been left open
Jet or impeller
is clogged
Water level in well is lower than
estimated
Motor is wired incorrectly
Standard
pressure
tank is water-
logged and has no air cushion
Pipe leak
Faucets or valves are open
Foot valve leaks
Pressure switch
is out of adjustment
Air charge too low in
Captive _
Tank
"
Model
390.251182
requires
30
pounds
and Models
390.251982
and 390.252282
require
40
pounds
for proper
operation
Pump is picking
up prime
Leak in suction
side of pump
Well is gaseous
Intermittent
over-pumping
of well
CORRECIIVE
ACI'ION
1. Be sure switch
is on
2. Replace fuse
3. Replace starting
switch
4. Refer to instructions
on wiring.
Check and tighten
all wiring.
5. Clean by sliding pieces
of plain paper between
contacts
1. Refer to instructions
on wiring
2. Check with power
company.
Install heavier wiring
if wire
size is too small. See wiring
instructions
3. See section
below on too frequent
cycling
1. In new installation:
a. Re-prime according
to instructions
b. Check all connections
on suction
line, air volume control,
and jet
c. Replace
foot valve
2. In installation
already in use:
a. Check all connections
on suction
line, air volume
control,
jet and shaft seal
b. Lower suction
line into water
and re-prime.
If receding
water level
in well exceeds
suction
lift, a deep well pump is needed
3. Clean jet or impeller
according
to instructions
4. Replace
check waive or foot valve
5. Thaw pipes. Bury pipes below frost line. Heat pit or pump
house.
6. Raise foot valve and/or strainer
above well bottom
1. A deep well jet pump may be needed (over 20 ft. to water)
2. Replace
with plastic pipe where possible,
otherwise
with new steel pipe
3. Use larger offset piping
1. Adjust or replace pressure switch
2. Close faucets
3. Clean jet or impeller
4. Check possibility
of using a deep well jet pump
5. Refertoinstructionsonwiring
2.
3.
4.
5.
6.
Drain tank to air volume
control tapping. Check air volume control for
defects. Check for air leaks at any connection
Check connections
Close faucets or valves
Replace foot valve
Replace pressure
switch
Disconnect
electrical
power
and open faucets until all pressure
is
relieved.
Using automobile
tire pressure
gauge, check
air pressure
in tank
at the valve stem located
at top of tank. If air pressure
is lower, pump
air
into tank from outside source until proper air pressure is reached. Check
air valve for leaks, using soapy solution,
and replace core if necessary.
1. AS soon as pump picks up prime,
all air will be ejected
2. Check suction
piping
3. Change
installation as described
in manual
4. Lower foot valve if possible,
otherwise
restrict discharge side of pump
Continued
on Page
14
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hydroglass 390.251982Hydroglass 390.251182

Table of Contents