SERVICE
REMOVING
MOTOR
FOR SERVICE
AND REPLACING
SHAFT
SEAL
Should repair or replacement
of motor
or seal be necessary,
the pump
need not be disconnected
from the piping.
(If it is necessary
to repair or replace
the motor,
ALWAYS re-
place the shaft seal, Key No. 7, Page 16. Therefore,
we sug-
gest that you order
this item and have on hand
for future
use).
Remove
motor
as follows:
1. Disassemble
pump
per disassembly
instruction
on Page
10.
2. Remove
diffuser
and impeller,
Key Nos. 8 and 9, Page 16,
from pump
back half.
--Rentove Impeller
as follows:
1. Loosen two-machine
screws
and remove
the motor
canopy,
Key No. 1A, Page 16.
2. Partially unscrew capacitor clamp and move capacitor to
one side.
3. Place a 7/16" open
end wrench
on the motor
shaft flat.
4. To remove,
turn the impeller
counterclockwise
(when
facing impeller).
The seal consists
of two parts,
a rotating member
and a float-
ing seat.
NOTICE: The highly polished
and lapped
faces of the seal are
easily damaged.
Read instructions
carefully.
5_ --Remove pump
back half from motor
by unscrewing
four
(4) nuts,
Key No. 20, Page 16, and pry back
half off of
motor
by inserting
two
(2) screwdrivers
between
the
back pump
half and the motor flange. Rotating
portion
of
seal will now come
off of shaft. Motor
is now separated
from pump
(see Figure 9).
6. Lay back half of pump
(large surface
down)
on a flat clean
surface
and tap out ceramic
seat. Clean seal cavity
from
which
seal was removed
and clean motor
shaft.
Install
New Seal As Follows:
1. Clean polished
surface
of floating
seat with clean cloth.
2. Wet the outer
edge of the O-Ring on the stationary
seat
with soap solution.
3. Press seat into cavity firmly and squarely
with finger pres-
sure. (Make sure polished
face of seal is facing towards
in-
side of pump).
If seat will not locate
properly,
place
a
cardboard
washer
over polished
face of seat and use piece
of 3/4" standard
pipe for pressing
purposes
(see Figure
11).
4'
Dispose
of cardboard
washer and make sure that l_lished
surface
of seat js free of dirt or foreign
particles
and has
not been scratched
or damaged
during
installation.
5. Inspect
shaft to make sure that it is clean.
6. Reassemble
back half of pump
to motor.
7. Apply soap solution
to inside diameter
and outer
face of
rubber drive ring.
8. Slide seal assembly
on shaft (sealing
face first) until rub-
ber drive ring hits shaft shoulder.
BE SURE you don't chip
or scratch
sealing face on shaft shoulder.
9. Screw
impeller
on shaft
until
impeller
hub
hits shaft
shoulder.
This will automatically
locate
seal in place and
move the sealing washer
face up against floating seat face
(see Figure 11).
Figure 9
475 0194
Figure
10
479 0194
Figure
I I
477 0194
11