Through-the-
Wall Installation
Make certain
a wall receptacle
is available
close to
the hole location
or make arrangements
to install
a receptacle.
The cord length
for the 115-volt models
is 72" to
the right and 47" to the left. For the 230/208wolt
models
the cord length
is 65" to the right and 39"
to the left.
The air conditioner
wall case may be installed
flush with the inside wall or flush with the outside
wall.
The finished
sides of the opening
should
be
structural
wall members.
Lintel-Use
a lintel in brick veneer
and brick and
block Vpes of wall to support
the bricks or blocks
above the opening.
Do not allow the wall case to
be used in lieu of a lintel.
Flas#ino-Install
flashing
(drip rail) as shown to
prevent
water fi'om dripping
inside the wall and
down the outside
of the building.
Brickveneer
Lintel angle
(if required}
Caulking
(on all
4 sides
on the
outside
of the
case}
Plaster
--
line
Trim
molding
--
{if desired}
Roomside
(Brip rail)
Caulking
(above &
belowthe
flashing)
1/4" min. extension
inside the wall from
the trim moulding
Mortar between the case and the brick all around
the case may be undercut
at about 45 ° fbr
improved
caulking.
Inside
,_
Top of
case
\,
Undercut
23
Caulking
Outside
mortar

Advertisement