Troubleshooting - Craftsman 919.167620 Owner's Manual

Permanently lubricated single stage portable air compressor
Table of Contents

Advertisement

Available languages

Available languages

_Risk
of Unsafe Operation. Unit cycles automatically
when
power is on. When servicing, you may be exposed to
voltage sources, compressed air, or moving parts. Before servicing
unit
unplug or disconnect
electrical supply to the air compressor, bleed tank of
pressure, and allow the air compressor to cool
PROBLEM
CAUSE
CORRECTION
Excessive
Pressure switch does not
Move Auto/Off lever to the
tank pressure
shut off motor when
"Off" position,
if the outfit
- safety valve
compressor reaches
does not shut off contact a
pops off.
"cut-out" pressure.
Trained Service Technician.
Pressure switch "cut-out"
Contact a Trained Service
too high.
Technician.
Air leaks at fit-
Tube fittings are not tight
tings,
enough.
Check valve seat damaged.
Air leaks at or
inside check
valve.
Air leaks at
pressure switch
release valve.
Air leaks in air
tank or at air
tank welds.
Defective pressure switch
release valve.
Defective air tank.
Air leaks
Leaking seal.
between head
and valve plate.
Tighten fittings where air can
be heard escaping. Check fit-
tings with soapy water solu-
tion, Do Not Overtighten.
A defective check valve results
in a constant air leak at the
pressure release valve when
there is pressure in the tank
and the compressor is shut
off. Replace check valve.
Refer to the "To Replace
Check Valve" in the Service
and Adjustment section.
Contact a Trained Service
Technician.
Air tank must be replaced.
Do
not repair the leak.
Risk of
--
Bursting
Do not drill into, weld or
otherwise
modify air tank or
it will weaken. The tank can
rupture or explode.
Contact a Trained Service
Technician.
19-ENG