Download Print this page

Craftsman 580.767100 Owner's Manual page 9

5.0 horsepower 2,100 psi 2.0 gpm

Advertisement

Available languages

Available languages

Slide the adjustable nozzle forward to low pressure
mode. Detergent cannot be applied with the nozzle
in high pressure position.
Make sure the garden hose is connected to the
water inlet. Check that the high pressure hose is
connected to the spray gun and the pump. Start
the engine.
Apply detergent to a dry surface, starting from the
bottom and working up.
Allow the detergent to "soak in" for 3-5 minutes
before rinsing. Reapply as needed to prevent
surface from drying.
For washing, start at lower portion of area to be
washed and work upward, using long, even,
overlapping strokes.
IMPORTANT:
You must flush the chemical injection
system after each use by placing the filter into a clean
bucket of water and running the pressure washer in
low pressure for 1-2 minutes.
Pressure
Washer
Rinsing
_
ARNING!
Be extremely careful if you use the
pressure washer from a ladder, scaffolding or
any other relatively unstable location. Pressure
in a running washer builds as you climb. When
you press the trigger, the recoil from the initial
spray could cause you to fall. The high pressure
spray could also cause you to fall if you are too
close to the cleaning surface.
For Rinsing:
Slide the nozzle backward to high pressure, press
the trigger and wait for the detergent to clear.
NOTE: You can also stop detergent flow by removing
detergent siphoning tube from container.
Keep the spray gun a safe distance from the area
you plan to spray.
Apply a high pressure spray to a small area, then
check the surface for damage. If no damage is
found, it is okay to continue cleaning.
Start at the top of the area to be rinsed, working
down with same overlapping strokes as you used
for washing and applying detergent.
Automatic
Cool Down System
(Thermal Relief)
If you run the engine on your pressure washer for
3-5 minutes without pressing the trigger on the spray
gun, circulating water in the pump can reach
temperatures
between 140-145°F. The automatic cool
down system engages at this temperature
and cools
the pump by discharging the warm water onto the
ground, preventing internal pump damage.

Advertisement

loading