Desa Comfort Glow CGCF26NRA Owner's Operation And Installation Manual page 21

Vent-free natural gas compact fireplace
Table of Contents

Advertisement

OWNER'S
MANUAL
TROUBLESHOOTING
Continued
,_
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's Instructions.
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These odors
will disappear over time.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Heater produces a clicking/ticking
noise
I. Metal expanding while heating or con-
1. This is common with most heaters. If
just after burner is lit or shut off
tracting while cooling
noise is excessive, contact qualified ser-
vice person
Heater produces unwanted odors
1. Heater burning vapors from paint, hair
spray, glues, cleaners, chemicals,
new
carpet, etc. (See IMPORTANT
state-
ment above)
2. Gasleak. SeeWarningstatementat
2. Locate and correct all leaks (see Check-
top of page
ing Gas Connections, page 13)
Heater shuts off in use (ODS operates)
1. Not enough fresh air is available
1. Open window and/or door for ventilation
2. Low line pressure
2. Contact local natural gas company
3. ODS/pilot is partially clogged
3. Clean ODS/pilot
(see Cleaning and
Maintenance, page 17)
Gas odor even when control knob is in OFF
1. Gasleak. SeeWamingstatementat
1. Locate and oorrect all leaks (sea Check-
position
top of page
ing Gas Connections, page 13)
2. Control valve defective
2. Replace control valve
Gas odor during combustion
1. Foreign matter between control valve
1. Take apart gas tubing and remove for-
and burner
eign matter
2. Gasleak.SeeWarningstatementat
2. Locate and correct all leaks (see Check-
top of page
ing Gas Connections, page 13)
1. Open window and ventilate room. Stop
using odor causing products while heater
is running
10_7