4.
On the Control Unit List panel, if a 2105 type of control unit already exists, then an "Add
like" operation can be used by inputting an A next to the 2105 type control unit and pressing
Enter. Otherwise, press F1 1 to add a new control unit.
Goto
Filter
--------------------------------------------------------------------------
Command ===> ___________________________________________ Scroll ===> PAGE
Select one or more control units, then press Enter.
/ CU
Type +
_ 3107 SCTC
_ 3108 SCTC
_ 3109 SCTC
_ 310A SCTC
_ 4000 3990-6
_ 4100 3990-6
_ 4200 3990-6
_ 4300 3990-6
_ 5000 3990
_ 5001 3990
_ 6000 3990
_ 6001 3990
_ 7000 3990
_ 7001 3990
F1=Help
F8=Forward
5.
On the Add Control Unit panel, input the following new information, or edit the information
if pre-loaded from an "Add like" operation, and then press Enter:
Control unit number
Control unit type: 2105
Switch information only if a switch exists. Otherwise leave switch and ports blank.
.-------------------------- Add Control Unit ---------------------------.
|
|
| Specify or revise the following values.
|
| Control unit number
|
| Control unit type
|
| Serial number
| Description
|
| Connected to switches
| Ports
. . . . . . . . . . . __
|
| If connected to a switch, select whether to have CHPIDs/link
| addresses, and unit address range proposed.
|
| Auto-assign
|
|
|
F1=Help
| F12=Cancel
'-----------------------------------------------------------------------'
6.
On the Select Processor / Control Unit panel, input an S next to the PROC. ID, and then press
Enter.
Goto
Filter
.---------------------- Select Processor / Control Unit ----------------------.
|
| Command ===> ___________________________________________ Scroll ===> PAGE
|
| Select processors to change CU/processor parameters, then press Enter.
|
| Control unit number . . : 8000
|
|
| / Proc. ID Att. (CUADD) +
| S PROD
| ***************************** Bottom of data ****************************** |
|
|
|
|
|
|
|
24
Mainframe operations
F2=Split
F3=Exit
F9=Swap
Backup
Query
Help
Control Unit List
Serial-# + Description
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
__________ ________________________________
F2=Split
F3=Exit
F9=Swap
F10=Actions
. . . . 8000
+
. . . . . 2105_________
. . . . . . . __________
. . . . . . . . new 2105 type for 80xx devices__
. . . __
__
__
__
__
. . . . . . . . 2
1.
Yes
2.
No
F2=Split
F3=Exit
F4=Prompt
Backup
Query
Help
Control unit type . . . : 2105
Log. Addr. -------Channel Path ID . Link Address + -------
1---- 2---- 3---- 4---- 5---- 6---- 7---- 8----
__
_____ _____ _____ _____ _____ _____ _____ _____
F12=Cancel
To add, use F11.
F4=Prompt
F5=Reset
F11=Add
F12=Cancel
+
__
__
__
__
__
+
__
__
__
__
__
+
F5=Reset
F9=Swap
Row 1 of 1 More:
|
Row 27 of 40