Operating specifications

This section provides some general specifications. For complete specifications, see the system site
preparation guide, available on the HP XP Disk Array website:
http://h18006.www1.hp.com/storage/xparrays.html

Temperature

Table 4 Temperature specifications
Temperature range type
Recommended operating temperature range
Operating temperature
Non-operating temperature range
Shipping and storage temperature (product
packed in factory packing)
Temperature shock immunity (maximum rate of
temperature change)

Humidity

Protect the disk array from excessive humidity. You should not observe condensation in or around the
product under any conditions. There is no procedure for recovery from moisture condensation.
Table 5 Humidity specifications
Humidity range type
Operating humidity range at 22 degrees C (71
degrees F)
Non-operating humidity range
Shipping and storage humidity range (product
packed in factory packing)
Operating maximum wet bulb temperature
Range
21 to 24 degrees C70 to 75 degrees F
16 to 32 degrees C61 to 89 degrees F
–10 to +43 degrees C14 to 109 degrees F
–25 to +60 degrees C–13 to +140 degrees F
10 degrees C per hour18 degrees F per hour
Non-condensing relative humidity (RH)
20% to 80%
8% to 90%
5% to 95%
26 degrees C (79 F)