Storage Tab: User-Defined Application Properties - HP StorageWorks All-in-One SB600c - Storage Blade User Manual

Hp storageworks all-in-one storage manager user guide (452695-003, june 2008)
Hide thumbs Also See for StorageWorks All-in-One SB600c - Storage Blade:
Table of Contents

Advertisement

Storage tab—Displays the user-defined application's storage space, including allocated space,
used space, free space, and the following storage allocation details:
Table 20 Storage tab: User-defined application properties
Property
Application Path
Protocol
Application Server Host Name
Application Server Volume -
Name
Application Server Volume -
Status
Application Server Volume -
Exclusive Storage
Application Server Volume - RAID
Level
Application Server Volume - RAID
Stripe Size
Application Server Volume - Read
Cache
Application Server Volume -
Write Cache
Application Server Volume -
Number of Hot Spares
Application Server Volume -
Mount Paths
Warning Threshold tab—Allows you to change the percent full warning threshold value for the
user-defined application. See
information.
Snapshots tab — Allows you to schedule snapshots of the user-defined application. For more
information, see
"Scheduling and running
Backup tab — Allows you to schedule backups of the user-defined application. See
"Scheduling
backups" on page 34 for more information.
Replication tab — Allows you to configure data replication of the user-defined application. See
"Running
replication" on page 37 for more information.
Value
Path to the file directory on the application server where the user-defined
application data is saved by the user-defined application. The file
directory is located on the volume created on the iSCSI LUN that was
exported by ASM to the application server.
Communication protocol used to transfer data between the server that
hosts the user-defined application and your HP All-in-One Storage
System.
Name of server that hosts the user-defined application.
Name of the volume on the application server to which the user-defined
application saves its data. The volume resides on the iSCSI LUN (logical
disk) exported by ASM to the application server.
Status of the volume on the application server where the user-defined
application data is stored.
Indicates if user-defined application storage is configured with exclusive
storage. See
Table 4
on page 21 for more information.
The RAID level to which the user-defined application storage is
configured. See
Customizing RAID levels
information.
The RAID stripe size to which the user-defined application storage is
configured. See
Table 4
Speeds up reads when enabled. This setting is determined by the
storage array, not ASM.
Speeds up writes when enabled. This setting is determined by the
storage array, not ASM.
The number of hot spares with which the database component storage
is configured. See
Table 4
Path the application server volume is mounted on. The volume is built
on the iSCSI LUN exported by ASM to the application server.
Setting a percent full warning threshold
snapshots" on page 31.
HP StorageWorks All-in-One Storage Manager
on page 23 for more
on page 21 for more information.
on page 21 for more information.
on page 24 for more