HP StorageWorks All-in-One SB600c - Storage Blade User Manual page 22

Hp storageworks all-in-one storage manager user guide (452695-003, june 2008)
Hide thumbs Also See for StorageWorks All-in-One SB600c - Storage Blade:
Table of Contents

Advertisement

Physical storage
Item
Description
Hot spare required
A hot spare is a hard drive reserved as a spare
for storage space configured as RAID 1, 1+0,
5, or 6. A hot spare automatically replaces a
hard drive when it fails. When the failed hard
drive is replaced, its replacement becomes the
new hot spare.
Minimum number of
The minimum number of physical disks that the
physical disks
allocated storage will be spread across. Storage
may be provisioned across more disks, but this
setting determines the minimum number of disks
reserved for the allocated storage.
Assigned logical disk
The storage area can be assigned to an existing
logical disk, or it can be assigned a new disk,
which is created upon completion of the
scheduled tasks for the storage wizard.
RAID stripe size
The number of bytes or kilobytes of data in each
RAID stripe (block of data). The RAID stripe size
selected affects performance. For the best
performance, select the stripe size closest to the
size of the files being saved.
Snapshot storage
Amount of storage space (as a percentage of
space (percentage of
the volume) that is reserved for storing snapshots
size)
of the storage area.
Other storage settings
Percent full warning
The percent full value that when reached
threshold
changes the storage status to Warning and
issues a warning alert. The warning indicates
that storage use has surpassed the percentage
full value. For example, if you enter 75%, you
see a warning (yellow asterisk) in the content
pane when storage is at 75 percent full.
Enforce allocated limit
Sets an enforced quota for the amount of storage
(quota)
available to a shared folder or local storage
application. When the storage space allocated
to a component is full, no further data can be
saved to this component.
Application server
Indicates whether the storage area is hosted on
volume mount type
a mount point or drive letter.
*After you have allocated and configured storage for an application component, user-defined application,
or shared folder using a wizard, you can change the allocated space size, change the percent full warning
threshold, and change the enforced allocated limit (shared folders and local storage applications). However,
you cannot change the RAID level, RAID stripe size, Hot Spares, or Physical Disk Type.
22
Hosting storage for applications and shared folders
Notes
A hot spare is assigned at the array
level. A LUN that does not require
a hot spare may be assigned one
anyway if another LUN on the same
array requires a hot spare. *
For better performance, increase
the minimum number of physical
disks
ASM provides the following values:
8 KB, 16 KB, 32KB, 64 KB, 128
KB, and 256 KB.*
This value may be modified in order
to match the change rate of the
data in the storage area.
The percent full warning threshold
is set by default to 80%. Percent full
warning threshold values are
ASM-specific; percent full warning
threshold values selected in the
Quota Management MMC snap-in
are not adopted by ASM. All other
Quota Management MMC snap-in
settings are adopted by ASM. See
Setting a percent full warning
threshold
on page 24.
This item is available for shared
folders and local storage
component. See
Enforcing an
allocated storage limit for shared
folders and local storage
applications
on page 25.
This setting does not apply to
shared folders.

Hide quick links: