INSTALLATION INSTRUCTIONS
INSTALLATION
WARNING:
Turn off and disconnect the unit before working.
1
(1)
Open the grille (Fig.1) by gently pulling
the arrow marked portion. Remove the
air filter (Fig.2) from the front panel.
Unscrew the screw fixing the front panel
to the chassis. (Fig.2)
Keep the screw as it will be used later.
CAUTION;
Do not provide stress to the opened grille. It
may damage the hinges. When the grille is
opened extremely wide, the hinge joints may
come off. In such case, push the hinge joint
into the hinge support (upper and lower accord-
ingly) and replace the grille.
(2)
Close the grille firmly, and remove the
front panel by pulling the front panel at
the lower corners towards you for about
3 cm (1" ). Then lift it up and pull it to-
wards you. (Fig.3)
2
(1)
Unscrew the 4 stopper screws (3 stopper
screws for model AF-A1288) of the cabi-
net (Fig.4). Keep the front screw and the
angle as they will be used later in step 6.
(2)
Slide the chassis out from the cabinet
by pulling the hand hold located at the
bottom center of the chassis. (Fig.4)
3
Attach the provided drain tray to the cabi-
net in case drainage becomes necessary.
Use the 2 short gold screws (1.2cm/0.5")
to fix it. (Fig.5)
Grille
Hinge
Air filter
2
1
Front panel
Grill
2
1
Cabinet
Chassis
Angle
Drain tray
Cabinet
E-3
Fig.1
Fig.2
Hinge support
Hinge joint
Front panel
Fig.3
Fig.4
Fig.5