Checking Operational Charging; Checking The Battery Pack - Lenovo IdeaPad N585 Hardware Maintenance Manual

Ideapad p580, p585, n580, n581, n585, n586 hardware maintanence manual (first edition)
Table of Contents

Advertisement

Lenovo IdeaPad P580/P585/N580/N581/N585/N586 Hardware
Maintenance Manual

Checking operational charging

To check whether the battery charges properly during operation, use a
discharged battery pack or a battery pack that has less than 50% of the total
power remaining when installed in the computer.
Perform operational charging. If the battery status indicator or icon does not
light on, remove the battery pack and let it return to room temperature. Reinstall
the battery pack. If the charge indicator or icon is still off, replace the battery
pack.
If the charge indicator still does not light on, replace the system board. Then
reinstall the battery pack. If it is still not charged, go to the next section.

Checking the battery pack

Battery charging does not start until the Power Meter shows that less than 95%
of the total power remains; under this condition the battery pack can charge to
100% of its capacity. This protects the battery pack from being overcharged or
from having a shortened life.
To check your battery, move your cursor to the Power Meter icon in the icon tray
of the Windows
percentage of battery power remaining is displayed. To get detailed information
about the battery, double-click the Power Meter icon.
Note: If the battery pack becomes hot, it may not be able to be charged. Remove
it from the computer and leave it at room temperature for a while. After it cools
down, reinstall and recharge it.
To check the battery pack, follow the steps below:
1. Turn off the computer.
2. Remove the battery pack and measure the voltage between battery terminals
3. If battery output voltage is less than +3.9V DC, the battery is damaged,
4. If the battery output voltage is more than +9V DC, measure the resistance
22
®
taskbar and wait for a moment (but do not click it), and the
1 (+) and 7 (-). See the following figure:
7(-)
6(-)
5
3 4
2(+)
1(+)
replace it.
If battery output voltage is less than +9V DC, perhaps the battery has entered
into overdischarge protection mode, pre-charge the battery with AC, please
replace the battery if battery capacity can not be charged over 0% within 2
hours.
between battery terminals 5 and 7. The resistance should be 4 to 30 KΩ.
If the resistance is not correct, replace the battery pack. If the resistance is
correct, check the system board function.
Terminal
Voltage (V DC)
1
+0 to +12.6
7
Ground (-)