INSTALLATION
25) Locate the ground lug.
For P36D-1 / P36-4 Only:
25a) By the receptical box, left of the unit.
For U32-5 Only:
25b) Located on the left side of the unit.
26) Connect one end of the supplied green
ground wire to the lug with the nut and
washer from the kit.
Ground
wire from
kit
27) Run the other end of the ground wire
and DC spark generator wires through
the bushing on the heat shield.
Heat Shield
20
28) Install the 1/2" bushing to the heat
shield.
29) Plug the DC spark generator wires to the
DC Sparker.
30) Connect the ground wire to the DC Sparker
mounting bracket.
31) Install the supplied battery into the DC
Sparker Box by opening the battery
compartment.
Battery
Compartment
32) Mount the heat shield to the DC Sparker.
Secure into place with the velcro, which is
provided in the kit.
33) Find a location which is not too hot and
is easy to reach for changing the battery.
Note: It should be kept away from the
chain.
Chain
34) Tie up the loose wires with the wire clip.
35) Check for gas leaks.
36) Check inlet and outlet pressures.
37) Check operation of fl ame control.
38) Check for proper fl ame appearance and
glow on logs.
NOTE:
The battery in the DC Sparker
Box will need to be replaced an-
nually.