1.10 Hardware Management Subsystem; Hardware Monitoring; Fan Monitoring; Chassis Intrusion And Detection - Intel DQ77MK Specification

Desktop board
Hide thumbs Also See for DQ77MK:
Table of Contents

Advertisement

Table 8 describes the LED states when the board is powered up and the LAN
subsystem is operating.
Table 8. LAN Connector LED States
LED
LED Color
Link
Green
Data Rate
Green/Yellow

1.10 Hardware Management Subsystem

The hardware management features enable the board to be compatible with the Wired
for Management (WfM) specification. The board has several hardware management
features, including the following:
Thermal and voltage monitoring
Chassis intrusion detection
1.10.1

Hardware Monitoring

The hardware monitoring and fan control subsystem is based on the Nuvoton
NCT6776D device, which supports the following:
Processor and system ambient temperature monitoring
Chassis fan speed monitoring
Power monitoring of +12 V, +5 V, +3.3 V, 3.3 Vstandby, V_SM, +VCCP, and
PCH V
CC
SMBus interface
1.10.2

Fan Monitoring

Fan monitoring can be implemented using Intel
software.
For information about
The functions of the fan headers
1.10.3

Chassis Intrusion and Detection

The board supports a chassis security feature that detects if the chassis cover is
removed. The security feature uses a mechanical switch on the chassis that attaches
to the chassis intrusion header. When the chassis cover is removed, the mechanical
switch is in the closed position.
For information about
The location of the chassis intrusion header
LED State
Condition
Off
LAN link is not established.
On
LAN link is established.
Blinking
LAN activity is occurring.
Off
10 Mb/s data rate is selected.
Green
100 Mb/s data rate is selected.
Yellow
1000 Mb/s data rate is selected.
®
Desktop Utilities or third-party
Product Description
Refer to
Section 1.12.2.2, page 41
Refer to
Figure 11, page 49
31

Hide quick links:

Advertisement

Table of Contents
loading