HP StorageWorks 1606 - Extension SAN Switch Release Note page 59

Hp storageworks fos 6.3.0b release notes (5697-0360, april 2010)
Hide thumbs Also See for StorageWorks 1606 - Extension SAN Switch:
Table of Contents

Advertisement

FVT: lun state never changed from write metadata to enable after GE
port enable.
Urouteshow will lag for several seconds at a time while displaying the
route info.
A LUN gets stuck in the Internal EE LUN State: Read Only (Internal
metadata key is in RO state).
After changing to non-FCS primary policy, web client can still activate
ACL policy.
WebTools shows high CPU usage (~80%) when port configuration
operation is performed in DCX.
FICON fcip block count mismatch on read emulation.
Unable to enable FMS Mode using WebTools on a DC04 SAN Director
with a 48 port blade.
Node descriptors are not shown for M-EOS switch in DCFM when using
FOS switch as the seed switch.
Get error CHASSIS, ERROR, SYS, FPGA error, DECRYPT_DECOM-
PRESS_FAIL : Cmd 0x932b6000, Myxid 0x6b3, PI/PT
0x41d00/0x41acc, Lun 0, PIOxid 0x131 PTRxid and the tape drive
is brought offline when labling a tape using TSM application.
[NSM] show message-stats command is missing mark option.
Detail view of WebTools Name Server Information should be greyed
out if no window will open.
Ports were found disabled after enabling Virtual Fabric (VF) through
DCFM on 8/40 SAN Switch.
Fabric watch: (java.lang.illegalArgumentException:Invalid logid) error
message box will appear when selecting Configuration report sub-tab
under Threshold configuration tab.
Port Movement from DCFM should be All-or-nothing behavior.
SCPD computes incorrect FCR domain ID in McDATA Fabric Mode
(interopMode 2).
No external Ethernet port association for pre-FIP FLOGI/FDISC unicast
frames.
Observed frame drops and IFCCs with lossless feature.
Encryption SAN Switch panic because KACd memory leak with multiple
get key operation.
FR zones cannot be created when defzone is set to "allaccess."
The lfcfg command shows incorrect data.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Erase the media outside of the
Encryption SAN Switch and then
continue on with label.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Set defzone to "noaccess."
Fixed in FOS 6.3.0
HP StorageWorks FOS 6.3.0b Release Notes