In IM2, mixed fabric with over 500 devices, name server counts do
not match for FOS and EOSc switches in the same fabric. EOSn count
matches FOS name server count.
FCIP VE port: Fast recovery does not handle pure out of order packets.
Firmwarecommit failed on Active CP with "missing
/etc/fabos/skm/IngrianNAE.properties"
Unable to launch WebTools on a DC SAN Director.
File SW_v5_8.mib has internal notation that it is Version 5.7.
CALD memory leak led to switch panic / fabric disruption.
Detected termination of 0.weblinker.fcg:2045 (1) during deleting lo-
gical switches.
Data Miscompare after Encryption SAN Switch power cycle.
Out of Memory due to switch not timing out in.telnetd processes.
Transmitted Rate / Received rates based on the Bytes Transmitted /
Bytes Received are greater than the peak rates (RateTxPeakByte &
RateRxPeakByte).
CP panic with FICUd crash occurred during supportsave operation.
Name Server daemon (nsd) panic occurs after enabling frame redirec-
tion.
RTWR error when going to translate domain.
400 Multiprotocol Router VE port doesn't recover after WAN issues.
50
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Execute the following commands on
both Active and Standby CPs after the
problem has occured. cp /etc/
fabos/skm/
IngrianNAE.properties.template
/etc/fabos/skm/
IngrianNAE.properties
firmwarecommit
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Reboot the switch.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
This can be avoided by doing one of
the following after enabling
FMSMODE for the first time: -
switchdisable/switchenable -
hafailover - hareboot - reboot.
Fixed in FOS 6.3.0
Workaround prior to code change:
Delay executing a cfgenable after a
cfgsave when there is frame RD zone.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0