Epson LX-90TM User Manual page 101

Printer interface cartridge for parallel interface systems
Hide thumbs Also See for LX-90TM:
Table of Contents

Advertisement

ESC EM
Format:
ASCII code:
Decimal:
Hexadecimal:
Comments:
Used with the optional cut-sheet feeder. When n = 0 the feeder is
turned off, when n = 4 it is turned on. Using DIP switch 1-3 pro-
duces the same effect.
ESC a
Format:
ASCII code:
Decimal:
Hexadecimal:
Comments:
Turns off the paper-out sensor
single sheet of paper. This command duplicates the function of DIP
switch 1-5. Some computer systems ignore this command. See page
D-3.
ESC 9
Format:
ASCII code:
Decimal:
Hexadecimal:
Comments:
Turns on paper-out sensor so that the printer beeper sounds and
printing stops when the printer runs out of paper.
ESC
EM
27
25
1B
19
ESC
8
27
56
1B
38
so that
ESC
9
27
57
1B
39
Cut Sheet Feeder Control
(n)
(n)
(n)
Disable Paper-Out Sensor
you can print to the end of a
Enable Paper-Out Sensor
C-25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lx-90

Table of Contents