Gigabyte GS-R12T4H2-RH Service Manual
Gigabyte GS-R12T4H2-RH Service Manual

Gigabyte GS-R12T4H2-RH Service Manual

1u rack mount server
Hide thumbs Also See for GS-R12T4H2-RH:

Advertisement

Quick Links

GIGABYTE
GS-R12T4H2-RH
1U Rack Mount Server
Service Guide
Dual Intel
Xeon LGA1366 Processor Serverboard
®
Rev. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte GS-R12T4H2-RH

  • Page 1 GIGABYTE GS-R12T4H2-RH 1U Rack Mount Server Service Guide Dual Intel Xeon LGA1366 Processor Serverboard ® Rev. 1.0...
  • Page 2: Preface

    PROVIDERS, your GIGABYTE office may have a DIFFERENT part number code to those given in the FRU list of this printed Service Guide. You MUST use the list provided by your regional GIGABYTE office to order FRU parts for repair and service of customer machines...
  • Page 3: Table Of Contents

    GS-R12T4H2-RH Rack Mount Server Table of Contents Preface ....................2 Safety, Care and Regulatory Information ..........5 System Specification ................9 System Hardware Installation ..............11 Remove the chassis cover................... 12 Installing the Processor ....................13 Installing the Heat Sink ....................14 Installing the Memeory Module ..................
  • Page 4 Table of Content Advanced ....................47 Processor Configuration ....................48 Processor Power Management ..................51 Memory Configuration ..................... 54 Advanced Chipset Configuration ................... 56 PCI Configuration ......................60 SATA Configuration ......................62 I/O DeviceConfiguration ....................65 Boot DeviceConfiguration ....................67 Thermal and Acoustic Configuration ................
  • Page 5: Safety, Care And Regulatory Information

    GS-R12T4H2-RH Rack Mount Server Safety, Care and Regulatory Information  Important safety information Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use. * The product should be operated only from the type of power source indicated on the rating label.
  • Page 6 Safety Information * To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord. * Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle. * Disconnect the modem cable before opening a product enclosure, touching or installing internal components, or touching an uninsulated modem cable or jack.
  • Page 7 GS-R12T4H2-RH Rack Mount Server the FCC. Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.
  • Page 8: Class A Equipment

    Safety Information NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100.
  • Page 9: System Specification

    Feature Summary System Specification Motherboard  GA-7TTSE-RH Processor Supported  Supports dual Intel Xeon processors ® ®  Intel Xeon Dual-Core/Quad-Core processor in LGA 1366 socket ®  Supports Intel Quickpath Interconnect up to 6.4 GT/s Chipset  Northbridge: Intel 5500 Chipset ®...
  • Page 10 GS-R12T4H2-RH Rack Mount Server (Support RAID 0, 1, 1E) (Option) Super I/O Controller  ITE IT8720F Super I/O Front I/O  2 X USB 2.0 connector Rear I/O  2 x P/S 2 ports  1 x Serial port  4 x USB 2.0 ports ...
  • Page 11: System Hardware Installation

    GS-R12T4H2-RH Rack Mount Server System Hardware Installation Pre-installation Instructions Perform the steps below before you open the server or before you remove or replace any component. 1. Back up all important system and data files before performing any hardware configuration. 2.
  • Page 12: Remove The Chassis Cover

    GS-R12T4H2-RH Rack Mount Server Remove the chassis cover. Step 1 Loosen the screw on the front chassis cover. Step 2 Push down the indentation located at the side of the back chassis. Step 3 Slide toward the top chassis cover. Step 4 Lift up to remove the top chassis cover.
  • Page 13: Installing The Processor

    Hardware Installation Process Installing the Processor Please make sure the CPU type and speed that are supported by the motherboard. Step 1 Raise the metal locking lever on the socket. Insert the CPU with the correct orientation. Step 2 The CPU only fits in one orientation. Step 3 Push the metal lever back into locked position.
  • Page 14: Installing The Heat Sink

    GS-R12T4H2-RH Rack Mount Server Installing the Heat Sink Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well remember to apply the thermal conductivity compound on the CPU. Step 2 Seat the heat sink in the retention modules with the four screws. Installation completed.
  • Page 15: Installing The Memeory Module

    GS-R12T4H2-RH Rack Mount Server Installing the Memeory Module Step 1. Insert the DIMM memory module vertically into the DIMM slot, and push it down. Step 2. Close the plastic clip at both edges of the DIMM slots to lock the DIMM module. NOTE! DIMM must be populated in order starting from DIMMA1/D1 sockets.
  • Page 16 Hardware Installation Process CPU2 CPU1 Code Code DDR_P1C2D0 DDR_P0C0D2 DDR_P1C2D1 DDR_P0C0D1 DDR_P1C2D2 DDR_P0C0D0 DDR_P1C1D0 DDR_P0C1D2 DDR_P1C1D1 DDR_P0C1D1 DDR_P1C1D2 DDR_P0C1D0 DDR_P1C0D0 DDR_P0C2D2 DDR_P1C0D1 DDR_P0C2D1 DDR_P1C0D2 DDR_P0C2D0...
  • Page 17 Hardware Installation Process U-DIMM Population Table Channel A Channel B Channel C P0C0D0 P0C0D1 P0C0D2 P0C1D0 P0C1D1 P0C1D2 P0C2D0 P0C2D1 P0C2D2 P1C0D0 P1C0D1 P1C0D2 P1C1D0 P1C1D1 P1C1D2 P1C2D0 P1C2D1 P1C2D2 Single-Rank Single-Rank Single-Rank Dual-Rank Dual-Rank Dual-Rank U-DIMM Single-Rank Single-Rank Single-Rank Single-Rank Single-Rank Single-Rank Dual-Rank Single-Rank...
  • Page 18 GS-R12T4H2-RH Rack Mount Server R-DIMM Population Table Channel A Channel B Channel C P0C0D0 P0C0D1 P0C0D2 P0C1D0 P0C1D1 P0C1D2 P0C2D0 P0C2D1 P0C2D2 P1C0D0 P1C0D1 P1C0D2 P1C1D0 P1C1D1 P1C1D2 P1C2D0 P1C2D1 P1C2D2 Single-Rank Single-Rank Single-Rank Dual-Rank Dual-Rank Dual-Rank Quad-Rank Quad-Rank Quad-Rank Single-Rank Single-Rank Single-Rank Single-Rank...
  • Page 19: Installing The Pci Expansion Card

    Hardware Installation Process Installing the PCI Expansion Card Step 1 Lift the riser bracket slightly, then pull it out from the server chassis. Step 2 Loosen the riser bracket screws. Step 3 Attach the mini card to the riser bracket and ecure the mini card with screws. Step 4 Attach the mini card to the riser bracket the other side.
  • Page 20 GS-R12T4H2-RH Rack Mount Server...
  • Page 21: Installing The Hard Disk Drive

    GS-R12T4H2-RH Rack Mount Server Installing the Hard Disk Drive Step 1 Press the release button. Step 2 Pull the locking lever to remove the HDD tray. Step 3 Slide hard disk into blank. Step 4 Secure the hard drive to the tray with four (4) screws as shown. Do not over tighten the screws.
  • Page 22: Hdd Security Lock

    Hardware Installation Process HDD Security Lock The HDD bays incorporate a security screw to prevent accidental HDD release. To engage the lock, turn the security screw clock-wise toward the Lock symbol. To disengage the lock, turn the security screw counter clock-wise toward the Unlock symbol as shown.
  • Page 23: Installing And Replacing The Fan Duct

    GS-R12T4H2-RH Rack Mount Server Installing and Replacing the FAN Duct Step 1 Remove the airducts from the chassis by pulling the rear edge in the direction of the arrow Step 2 With fan duct installation, align the fan duct with the guiding groove. Push down the fan duct into chassis until its firmly seats.
  • Page 24: Replacing The Fan Assemblly

    Hardware Installation Process Replacing the FAN Assemblly Step 1 Remove thefan assemble pulling the rear edge in the direction of the arrow Step 2 Lift up the fan assembly from the chassis. Step 3 Reverse the previous steps to install the replacement fan assembly.
  • Page 25: Replacing The Motherboard

    GS-R12T4H2-RH Rack Mount Server Replacing the Motherboard Step 1 Remove the chassis cover. See Removing the Chassis Cover on page 12. Step 2 Remove the fanduct from the chassis by pulling the rear edge in the direction of the arrow. Step 3 Remove the processor, heat sink, memory module, and PCI assembly.
  • Page 26: Replacing The Power Supply

    Hardware Installation Process Replacing the Power Supply Step 1 Remove the fanduct from the chassis by pulling the rear edge. Step 2 Disconnect the three power cables from the chassis as shown in the following image. Step 3 Remove the thress screws securing the power supply to the chassis. Step 4 Lift the power supply out of the chassis in the direction of the arrow.
  • Page 27 GS-R12T4H2-RH Rack Mount Server...
  • Page 28: Replacing The Chassis Cover

    GS-R12T4H2-RH Rack Mount Server Replacing the Chassis Cover Step 1 Replace the cover, and slide the chassis in the direction of the arrow  until the locking button clicks into place. Step 2 Tighten the securing screw  on top of the server.until the locking button clicks into place.
  • Page 29: Appearance Of Gs-R12T4H2-Rh

    GS-R12T4H2-RH Rack Mount Server Appearance of GS-R12T4H2-RH Front View of GS-R12T4H2-RH 1. HDD bay Open to install a hard drive. 2. HDD bay lock Turn this to lock and unlock the HDD bay. 3. HDD front release button Slide this release to the right and pull out lever to remove HDD bay.
  • Page 30: Rear View Of Gs-R12T4H2-Rh

    System Appearance Rear View of GS-R12T4H2-RH Power Module Connect the power cable to the socket. PS/2 port Connect the keyboard and mouse devices to this port. GLAN port Connect a RJ-45 jack to this port to link to a 10/100/1000 Megabit Ethernet LAN.
  • Page 31: Front Panel Led Indicator

    LED Description Front Panel LED Indicator Indicator Color State Description Power Green System has power applied to it status or ACPI S0 state Green Blink System is in ACPI S1 state (sleep mode) System is not powered on or in ACPI S5 state (power off) System is in ACPI S4 state (hlbernate mode)
  • Page 32 GS-R12T4H2-RH Rack Mount Server Indicator Color State Description LAN1 Green Link between system and activity network or no access Green Blink Network access LAN2 Green Link between system and activity network or no access Green Blink Network access...
  • Page 33: Lan Port Led Indicator

    GS-R12T4H2-RH Rack Mount Server LAN port LED Indicator       Name Color State Description Speed 10Mbps connection indicator Green 100Mbps connection Orange 1000Mbps connection Note: The server management port does not support 1000Mbps connection Link/activity Green Active connection indicator Green...
  • Page 34: Hard Disk Drive Led Description

    LED Description Hard Disk Drive LED Description           Description SAS/SATA HDD indicator Green HDD Prsent HDD access Blink (4Hz) HDD failure HDD removed HDD connected and Blink (1 Hz) rebuilding data HDD locate Blink (4Hz) Blink (4Hz)
  • Page 35: Gc-Bs14U-Rh Back Plane Board Components

    GS-R12T4H2-RH Rack Mount Server GC-BS14U-RH Back plane board Components Code Description Power Connector (14-pin) Power Connector (14-pin) 3~14 SF1~SF12 System fan connectors #1~12 CD-ROM_PWR1 CD-ROM power connector CD-ROM power connector SMBUS connector from M/B to B/P SGPIO_JP2 SGPIO connector from RAID card SGPIO_JP1 SGPIO connector from Enclosure IC(Motherboard) 20~23 SATA0~SATA3...
  • Page 36: System Block Diagram

    GS-R12T4H2-RH Rack Mount Server System Block Diagram VRD 11.1 VRD 11.1 CPU1 CPU2 Nehalem-EP Nehalem-EP Processor Processor LGA1366 LGA1366 Port 1 Port 1 PCIE x8 GEN2 PCIE x16 INTEL GLAN port x2 Kawela (x8 bandwidth) Tylersburg-24D COM2 PCIE x8 GEN2 PCIE X8 COM1 Switch...
  • Page 37: Connector Icon Description

    GS-R12T4H2-RH Rack Mount Server Connector Icon Description Suggest Icon Description Keyboard Mouse...
  • Page 38: Motherboard Placement And Jumper Setting

    Motherboard Compononts Motherboard Placement and Jumper Setting GA-7TTSE-RH Motherboard Component...
  • Page 39 GS-R12T4H2-RH Rack Mount Server Item Component Processor 1 socket Processor 2 socket SATA data cable cable connectors USB connector for internal USB (Tape device) CMOS battery 3-pin IPMB connector LPT_DEBUG connector Serial port connector HDD back plance borad connector Front panel connector SO-DIMM I/F PCI 32/33 MHz slot PCI- E x12 slot...
  • Page 40: Jumper Setting

    Jumper Setting Jumper Setting 1 ) BIOS_RVCR1 (BIOS Revocery jumper) 1-2 close: Normal operation. (Default setting) 2-3 close: Enable BIOS Recovery function. 2 ) CLR_CMOS1 (Clear CMOS jumper) You may clear the CMOS data to its default values by this jumper. Default value doesn’t include the “Shunter”...
  • Page 41 GS-R12T4H2-RH Rack Mount Server 3 ) CLR_RTC1 (Clear RTC jumper) 1-2 close: Normal operation. (Default setting) 2-3 close: Clear RTC status 4 ) ME_ENABLE (BMC Selection jumper) 1-2 Close: Normal operation. (Default setting) 2-3 Close: Enable BMC function. 5 ) PASS_DIS1 (Skip Supervisor password jumper) 1-2 Close: Normal operation.
  • Page 42: Expansion Card Components Description

    Jumper Setting Expansion Card Components Description The two riser cards installed in the PCI riser card bracket assembly povides support for both full- heoght and low-profile expansion cards. Full height and low profile PCI Express riser cards Code Description PCI-E_X16_1 Full-height riser slot PCI-E_2 Low-profile riser slot...
  • Page 43: Bios Setup

    GS-R12T4H2-RH Rack Mount Server BIOS Setup BIOS (Basic Input and Output System) includes a CMOS SETUP utility which allows user to configure required settings or to activate certain system features. The CMOS SETUP saves the configuration in the CMOS SRAM of the motherboard. When the power is turned off, the battery on the motherboard supplies the necessary power to the CMOS SRAM.
  • Page 44: Getting Help

    BIOS Setup GETTING HELP Main Menu The on-line description of the highlighted setup function is displayed at the bottom of the screen. Status Page Setup Menu / Option Page Setup Menu Press F1 to pop up a small help window that describes the appropriate keys to use and the possible selections for the highlighted item.
  • Page 45: Main

    GS-R12T4H2-RH Rack Mount Server Main Once you enter Phoenix BIOS Setup Utility, the Main Menu (Figure 1) will appear on the screen. Use arrow keys to select among the items and press <Enter> to accept or enter the sub-menu. Figure 1: Main System Date Set the System Date.
  • Page 46: Total Memory

    BIOS Setup Total Memory The BIOS determines how much total memory is present during the POST.
  • Page 47: Advanced

    BIOS Setup Advanced About This Section: Advanced With this section, allowing user to configure your system for advanced operation. User can set the Processor configuration, Memory configuration, Advanced chipset configuration, PCI configuration , SATA configuration, I/O device configuration, Boot configuration, and Thermal and acoustic configuration.
  • Page 48: Processor Configuration

    GS-R12T4H2-RH Rack Mount Server Processor Configuration...
  • Page 49: Active Processor Cores

    BIOS Setup Processor Configuration This category includes the Processor information of CPU Speed, Processor ID ,Processor L2 / L3 Cache, and QPI Frequency. And setup sub-menu for CPU Power Management. Please note that setup menu options will be variable depends on the type of CPU. Multiprocessor Specification This option allows user to configure the multiprocessor(MP) specification revision level.
  • Page 50: Thermal Management

    GS-R12T4H2-RH Rack Mount Server Machine Checking Enabled Enable Machine Checking. (Default setting) Disabled Disable Machine Checking Fast String Operations Enabled Enable Fast String Operations. (Default setting) Disabled Disable Fast String Operations. Set Max Ext CPUID=3 Enabled Enable Set Max Ext CPUID=3. Disabled Disable Set Max Ext CPUID=3.
  • Page 51: Processor Power Management

    GS-R12T4H2-RH Rack Mount Server Processor Power Management Figure 2-1-1: Processor Power Management EIST (GV3) & C State Enabled Enable EIST (GV3) and C State items. (Default setting) Disabled Disable EIST (GV3) and C State items. EIST (GV3) Enabled Enable EIST (GV3. (Default setting) Disabled Disable EIST (GV3).
  • Page 52: Turbo Mode

    BIOS Setup SW_ALL In SW_ALL mode, the OS Power Manager is responsible for coordinating the P-state among loical processors with dependencies and must initiate the transition on all of those Logical Processors. SW_ANY In SW_ANY mode, the OS Power Manager is responsible for corrdinating the P-state among logical processors with dependencies and may initiate the transition on any of those Logical Processors .
  • Page 53 GS-R12T4H2-RH Rack Mount Server state. (Default setting) Disabled Disable CPU C6 Report. CPU C7 Report Enabled Desire state for the Nehalem core C7 state include in the CST as ACPI C3 state. (Default setting) Disabled Disable CPU C7 Report. Package C State Limit Desired state for the C-State package limit.
  • Page 54: Memory Configuration

    BIOS Setup Memory Configuration...
  • Page 55: Memory Information

    GS-R12T4H2-RH Rack Mount Server Memory Information These following items display all information of current Base Memory, Extended Memory, , and installed DIMM Status. These items are display-only which is determined by POST (Power On Self Test) of the BIOS. Memory Control Settings Manual Select ‘Manual”...
  • Page 56: Advanced Chipset Configuration

    BIOS Setup Advanced Chipset Configuration...
  • Page 57 GS-R12T4H2-RH Rack Mount Server Figure 2-3-1: Intel VT for Directed I/O (VT-d)
  • Page 58 BIOS Setup Intel VT for Directed I/O (VT-d) Enabled Intel VT for Directed I/O (VT-d). (Default setting) Disabled Disable Intel VT for Directed I/O (VT-d). Interrupt Remapping Enabled Enable Interrupt Remapping. (Default setting) Disabled Disable Interrupt Remapping. Coherency Support Enabled Enable Coherency Support.
  • Page 59 GS-R12T4H2-RH Rack Mount Server Select 2GB as granularity of PCI hole. QPI Control Settings Enabled Enable QPI Control settings. (Default setting) Disabled QPI Control settings. QPI Link Fast Mode Enabled Enable QPI Link Fast Mode. (Default setting) Disabled Disable QPI Link Fast Mode. QPI Frequency Selection Identify the desire value of QPI frequency.
  • Page 60: Pci Configuration

    BIOS Setup PCI Configuration Figure 2-4: PCI Configuration Onboard LAN iSCSI Boot ROM Enabled Enable Onboard LAN iSCSI Boot ROM. Disabled Disable this function. (Defualt setting) Onboard LAN1 Control Enabled Enable Onboard LAN controller. (Defualt setting) Disabled Disable this function. LAN1Option ROM Enabled Enable onboard LAN1 device and initialize device expansion...
  • Page 61 GS-R12T4H2-RH Rack Mount Server LAN2Option ROM Enabled Enable onboard LAN2 device and initialize device expansion ROM. (Default setting) Disabled Disable this function. Legacy USB Support This option allows user to function support for legacy USB. Enabled Enables support for legacy USB (Default setting) Disabled Disables support for legacy USB.
  • Page 62: Sata Configuration

    GS-R12T4H2-RH Rack Mount Server SATA Configuration Figure 2-5: SATA Configuration...
  • Page 63: Serial Ata

    BIOS Setup Serial ATA Enabled Enables on-board serial ATA function. (Default setting) Disabled Disables on-board serial ATA function. Native Mode Operation This option allows user to set the native mode for Serial ATA function. Auto Auto detected. (Default setting) Serial ATA Set Native mode to Serial ATA.
  • Page 64 BIOS Setup Auto: Set parameters automatically. (Default setting) CD-ROM: Use for ATAPI CD-ROM drives or double click [Auto] to set all HDD parameters automatically. ATAPI Removable: Removable disk drive is installed here. Multi-Sector Transfer This field displays the information of Multi-Sector Transfer Mode. Disabled: The data transfer from and to the device occurs one sector at a time.
  • Page 65: I/O Deviceconfiguration

    BIOS Setup I/O DeviceConfiguration Figure 2-6: I/O Device Configuration Serial Port A This allows users to configure serial prot A by using this option. Enabled Enable the configuration. (Default setting) Disabled Disable the configuration. Base I/O Address/IRQ 3F8/IRQ4 Set IO address to 3F8/IRQ4.(Default setting) 2F8/IRQ3 Set IO address to 2F8/IRQ3.
  • Page 66 GS-R12T4H2-RH Rack Mount Server Base I/O Address/IRQ 3F8/IRQ4 Set IO address to 3F8/IRQ4. 2F8/IRQ3 Set IO address to 2F8/IRQ3. (Default setting) 3E8/IRQ7 Set IO address to 3E8/IRQ7. 2E8/IRQ5 Set IO address to 2E8/IRQ5.
  • Page 67: Boot Deviceconfiguration

    BIOS Setup Boot DeviceConfiguration Figure 2-7: Boot Configuration Boot -time Diagnostic Screen When this item is enabled, system will shows Diagnostic status when system boot. Enabled Enable Boot-time Diagnostic screen. Disabled Disable this function. (Default setting) Post Error Pause The category determines whether the computer will stop if an error is detected during power up. All Error Whenever the BIOS detects a non-fatal error the system will be stopped.
  • Page 68 GS-R12T4H2-RH Rack Mount Server NumLock This option allows user to select power-on state for NumLock. Enable NumLock. (Default setting) Disable this function.
  • Page 69: Thermal And Acoustic Configuration

    BIOS Setup Thermal and Acoustic Configuration Figure 2-8: Thermal and Acoustic Configuration Open loop Thermal Throttle Enabled Open loop Thermal Throttle. (Default setting) Disabled Disable Open loop Thermal Throttle. Temperature Chassis inlet This item is user defined. Use nuber key to adjust desired value. Temperature Rise This item is user defined.
  • Page 70 GS-R12T4H2-RH Rack Mount Server Close loop Thermal Throttle Enabled Close loop Thermal Throttle. (Default setting) Disabled Disable Close loop Thermal Throttle. Temperature hysteresis This item is user defined. Use nuber key to adjust desired value. Temperature guardband This item is user defined. Use nuber key to adjust desired value. Temperature Chassis inlet This item is user defined.
  • Page 71: Power

    GS-R12T4H2-RH Rack Mount Server Power Figure 3: Power After Power Failure This option provides user to set the mode of operation if an AC / power loss occurs. Power On System power state when AC cord is re-plugged. Stay Off Do not power on system when AC power is back.
  • Page 72: Security

    BIOS Setup Security           About This Section: Security In this section, user can set either supervisor or user passwords, or both for different level of password securities. In addition, user also can set the virus protection for boot sector. Figure 4: Security Set Supervisor Password You can install and change this options for the setup menus.
  • Page 73: Set User Password

    GS-R12T4H2-RH Rack Mount Server Set User Password You can only enter but do not have the right to change the options of the setup menus. When you select this function, the following message will appear at the center of the screen to assist you in creating a password.
  • Page 74: Server

    BIOS Setup Server Figure 5: Server...
  • Page 75: System Management

    GS-R12T4H2-RH Rack Mount Server System Management...
  • Page 76 BIOS Setup System Management This category allows user to view the system management features. Including information of Motherboard Hardware information and software information. BMC IP Address Source Address obtained by BMC running DHCP or Static address. Option available: DHCP, Static.
  • Page 77: Console Redirection

    GS-R12T4H2-RH Rack Mount Server Console Redirection Figure 5-2: Console Redirection Console Redirection If this option is set to enabled, it will use a port on the motherboard to run console redirection function. On-board COM A Use Serial Port A as the COM port address. On-board COM B Use Serial Port B as the COM port address.
  • Page 78: Terminal Type

    BIOS Setup This option allows user to set the specified baud rate. Options 300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, 115.2K. Terminal Type This option allows user to select the specified terminal type. This is defined by IEEE. Options VT100, VT100 8bit, PC-ANSI 7bit, PC-ANSI, VT100+, VT-UTF8, ASCII.
  • Page 79: Boot

    GS-R12T4H2-RH Rack Mount Server Boot Figure 6: Boot Boot Priority Order This field determines which type of device the system attempt to boot from after PhoenixBIOS Post completed. Specifies the boot sequence from the available devices. If the first device is not a bootable device, the system will seek for next available device. Key used to view or configure devices: Up and Down arrows select a device.
  • Page 80: Exit

    BIOS Setup Exit Figure 7: Exit About This Section: Exit Once you have changed all of the set values in the BIOS setup, you should save your changes and exit BIOS setup program. Select “Exit” from the menu bar, to display the following sub-menu.
  • Page 81: Discard Changes

    GS-R12T4H2-RH Rack Mount Server      Load Settup Default if you highlight this item and press Enter, a dialog box asks if you want to install optimal settings for all the items in the Setup utility. Press the Y key to indicate Yes, and then press Enter to install the optimal settings.