Installation - Sears 390.262451 Owner's Manual

"hydro-glass" high pressure sprinkler pump
Table of Contents

Advertisement

2. Whenthepumpis setawayfromthepointsof water
use,the discharge pipesizeshouldbe
increased to
reduce pressure losses caused by friction,
o Up to 100' run: Same size as pump discharge port.
= 100' to 300' run: Increase one pipe size,
= 300' to 600' run: Increase two pipe sizes.
LAWN SPRINKLING
APPLICATION
This pump is designed for lawn sprinkling° It is designed
to deliver plenty of water at full sprinkler pressure It can
pump from a pond, cistern or well points
Pump discharge can be divided to supply two (2) or more
sprinkler
systems• A suggested multiple
discharge
to
service is shown in Figure 7, Page 4_
Do not use in a pressure tank or booster pump appli-
cation.
Pump/Piping
installation
PUMP
INSTALLATION
NOTICE:
Use Teflon tape supplied
with the pump for
making all threaded connections to the pump itself
Do
not use pipe joint compounds on the pump: they can
react with the plastic in the pump components.
1, Bolt pump to solid, level foundation
2. Support all piping connected to the pump,
3. Wrap t-1/2 to two layers of Teflon tape clockwise (as
you face end of pipe) on all male threads
being
attached to pump.
4o Tighten joints
hand tight plus 1-1/2 turns° Do not
overtighten.
NOTICE: Install pump as close to well head as possible.
Long piping runs and many fittings create friction
and
reduce flow.
NOTICE: For long horizontal pipe runs, install a priming
tee between
check valve and well
head as shown
in
Figure 5, Page 4, For driven point installations,
install a
check valve as shown in Figure 6, Page 4. Be sure check
valve flow arrow points toward pump
Use schedule 80 or iron pipe, See "Well Pipe Installation"
for more information_
ill ,
Figure 8 - Bolt Pump Down
Figure 9- Independently
Support All Piping
Attached To Pump
Pipe Joint Compound Will
.........Damage Plastic
No Air Leaks in Suction P}_
!:,
",,Air Fto;s "
::::::::::::::::::::::::::::::::::::
• :::::::::::::::::::::::
Use Teflon Tape
Figure ! 0 - Use Teflon Tape Or Plasto-Joint Stik on
Pipe Joints and Connections to Pump
From
Well
r/ ooo"
Hand Tight Plus 1-112 Turns With Wrench
748 0993
Figure 11 - Don't Overtighten

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

390.262551390.262651

Table of Contents