Installation - Sears 390.262451 Owner's Manual

"hydro-glass" high pressure sprinkler pump
Table of Contents

Advertisement

Well Pipe Installation
NOTICE:
Use the installation
method
below
which
matches your well type°
CASED WELL INSTALLATION
Io Inspect foot valve to be sure it works freely. Inspect
strainer to be sure it is clean°
2o Connect foot valve and strainer to the first length of
suction pipe and lower pipe into well
Add sections of
pipe as needed, using Teflon tape on male threads_ Be
sure that all suction pipe is leakproof or' pump will
lose prime and fail to pump. Install foot valve 10 to 20
feet below the lowest level to which water will drop
while pump is operating (pumping water level). Your
well driller can furnish this information.
3. To prevent
sand and sediment
from entering
the
pumping system, the foot valve/strainer
should be at
least 5 feet above the bottom of the well
4_ When the proper depth is reached, install a sanitary
well seal over the pipe and in the well casing. Tighten
the bolts to seal the casing.
5o When using a foot valve, a priming tee and plug as
shown in Figure 5 are recommended
plug
Suction/
pipe
Primingtee
Standingwater
level (pump off)
Draw_ewn water
levet (pump on)
1'(3-s m)
At feast 5 feet (1 5 m)
Figure 5 - Cased/Dug
Well Installation
DUG
WELL INSTALLATION
Io Same as cased well installation.
DRIVEN
POINT
INSTALLATION
I_ Connect
the suction
pipe to the drive
point
as
illustrated
in Figure 6o Keep horizontal
pipe run as
short as possible,
use Teflon
tape on male pipe
threads
Multiple
well points may be necessary to
provide sufficient water to pump_
[_ck
vaive
_
(trlve p_pe
coupling
.,__Wel_ point
_.,..._Dr'_ven
point
Figure 6 - Driven Point Installation
Priming
Plug
Valve
846 0494
Figure 7 - Multiple
Discharge
2.. Install a check valve in horizontal pipe. Flow arrow on
check valve must point toward pump.
HORIZONTAL
PIPING FROM WELL TO PUMP
i.
Never install a suction pipe that is smaller than the
suction port of the pump_
2. To aid priming on well point installations, install a line
check valve as shown in Figure 6. Be sure check valve
flow arrow point toward pump.
DISCHARGE
PIPE SIZES
I,
If increasing discharge pipe size, install reducer in
pump discharge porL Do not increase pipe size by
stages°