Troubleshooting Guide - Craftsman 919.670070 Owner's Manual

120/240 volt 7000 watt generator
Hide thumbs Also See for 919.670070:
Table of Contents

Advertisement

PROBLEM
CA USE
Engine wifl not start
No electHcM
output
Repeated
circuit breaker
tripping
Generator
overheating the
circuit
breaker depressed
1.
Low on fuei or oil
2.
Ignition switch in "Off" position.
3.
Fauityspark
piug,
4.
Choke in wrong position.
5.
Fuei shut-off vaive in dosed
position.
6.
Unit ioaded during start-up.
7.
Spark piug wire ioose,
1.
Fauity receptacb.
2.
Circuit breaker kicked out.
3.
Defective capacitor.
4,
Faulty power cord.
5,
GFCI receptacle circuit breaker
kicked out,
1,
Overload
2,
Faulty cords or equipment.
1,
Generator overloaded,
2,
Insufficient ventilation,
1, Add fuel or oii,
2, Turn to "ON" position
3,
Replace spark plug,
4, Adjust choke accordingly,
5, Open fuel shut-off valve,
6, Remove load from unit,
7, Attach wire to spark plug,
1.
Have Authorized
Sears Service
Center
replace.
2.
Depress
and reseL
3.
Have Authorized
Sears Service
Center
replace
capacitor.
4.
Repair or replace
cord.
Depress
and reseL
5.
.
2,
Reduce
load.
Check for damaged,
bare, or
frayed
wires on equipment.
Replace.
1, Reduce load,
2, Move to adequate supply of
fresh air,
21 -- ENG