Gator Module Port Status Display; The Chassis Manager Window - Enterasys GatorMIM and GatorStar User Manual

Enterasys networks gatormim and gatorstar user's guide
Table of Contents

Advertisement

The Gator Module View

Gator Module Port Status Display

The Port Status display varies for each module type. The status conditions for the
GatorMIM CS are:
ON (Green)
OFF (Red)
? (Blue)
The status conditions for the GatorStar GX-M are:
ENB (Yellow/Enabled)
DIS (Red/Disabled)
? (Blue/Unknown)
NLK (Yellow/No Link)

The Chassis Manager Window

The Chassis Manager window,
MIBs and the MIB components — and, therefore, the functionality — supported
by the currently monitored device.
1. Select Help—>MIBs Supported in the menu bar. The Chassis Manager
2-6
window opens.
The port is on-line and forwarding packets
across the Gator Module from one network
segment to another.
The port has been disabled by management; no
traffic can be received or forwarded on this port.
The status of ports cannot be determined by the
software.
The port is enabled, but not connected to a
device; hence, no packets are being forwarded.
The port has been disabled by management; no
traffic can be received or forwarded on this port.
The status of ports cannot be determined by the
software.
The port has been disabled automatically
because of excessive SWOP, activity, or
jabbering. You will be able to re-enable the port
when the offending condition no longer exists.
Figure
2-4, is a read-only window that displays the
Viewing Device Information

Advertisement

Table of Contents
loading

This manual is also suitable for:

GatormimGator star

Table of Contents