Installations - COZY DVCF407B-R Installation And Operation Instructions Manual

Direct vent counterflow wall furnace
Table of Contents

Advertisement

14-PEK
KIT
INSTRUCTIONS
(14' PLUG EXTENSION
KIT)
FOR NON-RECESSED
INSTALLATIONS
ONLY
90 De_ee
Outside
--'+
Corner
©
3 FT.
SECTION
©
3 FT.
SECTION
®
MODEL NO.
DVCF40
DVCF55
DVCF65
LENGTH OF BOTTOM
SECTION (REF. 4)
PLASTIC RACEWAY
5-5/16 Inches
14 Inches
14 Inches
NOTE: Above lengths terminate approximately
2 inches above floor.
UNITS
WITH
TERMINAL
BOARD
STEP #
1. Turn heater off following
Section 3 in "Lighting
Instructions"
and allow to cool.
2. Turn offall electricity
to heater.
3. Remove top louver assembly, tan shroud and fan
blade.
4. Loosen two screws on romex connector.
5. Remove junction box cover plate.
6. Disconnect
three power cord terminals
and pull
power cord out of top of heater.
7. Insert power cord provided in kit through romex
connector and plug onto terminal board following
wiring diagram found in lighting and operating
instructions.
8. Tighten two screws on romex connector.
9. Replace junction
box cover plate.
10. Replace
fan blade, fan shroud
and top louver
assembly.
11. Snap 90 degree outside corner (Ref. 1) onto 3
foot section (Ref. 2) plastic raceway. Insert power
cord and remove blue backing from adhesive strip
on raceway and apply to side of heater.
12. Insert power cord into second 3-foot section of
raceway
(Ref. 3) and remove blue backing and
apply to side of heater, butting up against bottom
of other section.
13. Cut 14-inch long bottom section to required length
(see chart), insert power cord, remove backing
and apply to side of heater.
14. Plug power cord into wall receptacle.
15. Light the heater following lighting instructions.
Page 15