Exhaust Air Connection - Bosch Nexxt Series Operating, Care And Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

10, Check the U,L, strain relief
clamp to make sure that it is
tight and cannot be turned,
11. Replace the cover on the
terminal block and fasten in
place,
]]Make
sure that the U,L, strain
relief clamp is outside the
cover!
The appliance
is now ready to be
plugged
into the 4 wire receptacle
of the power rating,
Connecting
3-wire
power
supply
cord
1. Remove the screws from the
cover of the terminal block
located at the top rear of the
appliance.
2. Make sure that there is
a grounding
strap.
3. Fix the strain relief clamp to the
angle bracket. Tighten the nut.
4. Loosen the 2 screws labeled L
and the screw labeled N in the
terminal block.
5. Thread the 3 wire cable
through the U.L. strain relief
clamp.
6. Tighten the screws (2.5 Nm) on
the U.L. strain relief clamp so
that the power cord cannot be
moved.
7. Attach the 2 power cord outer
conductors
(red and black) to
the 2 terminals
labeled L and
the remaining
power cord
conductor
(white) to the
terminal labeled N.
8. Tighten all 3 screws (3 Nm) so
that the power conductors
are
held in ptace securely.
9. Check the U.L. strain relief
clamp to make sure that it is
tight and cannot be turned.
10. Replace the cover on the
terminal block and fasten in
place.
E_
Make sure that the U.L. strain
relief clamp is outside the
cover!
Additional
grounding
procedure
Some local regulations
may
require a separate ground.
In such cases, the required
accessory
ground wire, clamp
and screw must be purchased
separately.
Never ground the dryer to
plastic plumbing
lines, gas lines
or water pipes.
Grounding
instruction
This appliance
must be grounded.
In the event of a malfunction
or
breakdown,
grounding
will reduce
the risk of electric shock by
providing
a path of least resistance
for the electric current.
For Canada the dryer comes with a
cord which has an equipment
grounding
conductor
and a
grounding
plug. The plug must be
plugged
into an appropriate
outlet
which has been properly
installed
and grounded
in accordance
with
all local regulations
and ordinances.
Improper connection
of the
equipment
grounding
conductor
may result in electric shock,
Have the appliance
checked
by
a qualified electrician
or service
technician
if you are in doubt as
to whether the dryer has been
properly grounded,
Exhaust air connection
1. To reduce the risk of fire, this
dryer MUST BE EXHAUSTED
OUTDOORS.
2. To reduce the risk of fire, do
not use the ductwork
longer
than recommended.
3. DO NOT use a plastic or
non-metal
duct with this dryer.
4. DO NOT use a duct smaller
than 4 inches in diameter.
5. DO NOT use exhaust hoods
with magnetic
latches.
6. DO NOT exhaust the dryer into
a chimney, furnace cold air
duct, attic, crawl space, or any
other ductwork
used for
venting.
7. DO NOT install a flexible duct
in an enclosed
watt, ceiling or
floor.
8. DO NOT crush or kink the
duct.
9. Do clean and inspect the
exhaust
system on a regular
basis; at least once a year.
10o The exhaust duct must
terminate
in a manner to
prevent back drafts or entry of
birds or other wildlife.
The Bosch dryers are intended
to
be vented outdoors.
To prevent
build up of moisture
and
accumulation
of tint indoors,
as well
as to maintain maximum
drying
efficiency, it is recommended
that
the dryer is vented outdoors.
Exhaust
air outlet
on the dryer
The dryer is delivered with an
exhaust air outlet on the rear of the
appliance.
To take account
of the spatial
requirements
and an existing
exhaust air system, the following
connection
options are possible for
the exhaust
air outlet:
on right side of the appliance,
on the underside
of the
appliance.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents