Product Data Sheets; Interior Water Filtration System - Whirlpool GI5FSAXVY - 24.9 cu. ft. Refrigerator User Manual

User guide
Table of Contents

Advertisement

Available languages

Available languages

PRODUCT DATASHEETS
Interior Water Filtration System
Model 67003523-750
Capacity
750 Gallons
(2839 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of Lead,
Mercury, Atrazine,
Toxaphene,
Cysts, Turbidity, Asbestos
and Lindane.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances
listed below. The
concentration
of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the
permissible
limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
1.88 mg/L
2.0 mg/L _+10%
0.06 mg/L
**
0.05 mg/L
96.84
>97.26
Particulate Class I*
85% reduction
5,700,000 #/mL
Atparticles/mleast
10,000L
69,000 #/mL
30,583 #/mL
98.94
99.52
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum%
Average%
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
0.153 mg/U
0.15 mg/L + 10%
< 0.001 mg/L
< 0.001mg/L
>99.29%
>99.35%
Lead: @ pH 8.5
0.010 mg/L
0.150 mg/U
0.15 mg/L _+10%
< 0.001 mg/L
< 0.001mg/L
>99.29%
>99.33%
Mercury: @ pH 6.5
0.002 mg/L
0.006 mg/L
0.006 mg/L + 10%
0.0005 mg/L
0.0003 mg/L
90.91
95.70
Mercury: @ pH 8.5
0.002 mg/L
0.006 mg/L
0.006 mg/L _+10%
0.0015 mg/L
0.0008 mg/L
75.93
86.22
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 _+10%
< 0.001 mg/L
< 0.001mg/L
91.67%
92.97%
Atrazine
0.003 mg/L
0.009mg/L
0.009 mg/L _+10%
< 0.002 mg/L
< 0.002 mg/L
75.31%
76.99%
Asbestos
99%
155 MF/L
107to 108fibers/L tt
< 1 MF/L
< 1 MF/L
>99.99%
>99.99%
Live Cysts _
>99.95%
166,500 #/L
50,000/L min.
< 1 #/U
< 1 #/U
>99.99
>99.99
Turbidity
0.5 NTU
10.7 NTU
11 _+1 NTU
0.49 NTU
0.31 NTU
95.2
97.09
Lindane
0.0002 mg/L
0.002 mg/L
0.002 _+10%
< 0.0001mg/L
0.000 mg/L
96.50%
98.72%
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (41
71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter
replacement requirements
be carried out for the product to
perform as advertised.
The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
When 90% of the filter's rated life is used, the yellow (Order)
light comes on. When 100% of the filter's rated life is used, the
red (Replace) light comes on, and it is recommended
that you
replace the filter. For models without filter status lights,
replace the filter every 6 months. Use replacement filter model
67003523; order Part Number 4396395.2007
suggested retail
price of $49.99 U.S.A./S65.95 Canada. Prices are subject to
change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Refer to the "Water Filtration System" section for the
Manufacturer's
name and telephone number.
3.7 kPa). Temp. = 68°F to
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
35 - 120 psi (241 - 827 kPa)
Water Temperature
33 ° - 100°F (1° - 38°C)
Service Flow Rate
0.78 gpm (2.9 L/min.) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tThese contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
16