Amana ARB1905CC0 Owner's Manual page 18

Bottom freezer refrigerator
Table of Contents

Advertisement

Trouble
Shooting
OPERATION
(continued)
TOPIC
POSSIBLE
CAUSE
SOLUTION
Refrigerator
runs too
Controls need to be adjusted.
frequently
(continued)
Door is not closing properly.
ICE
See controls section in your Owner's Manual for assistance
in how to adjust your controls.
Refrigerator
is not level. See How to Level Your
Refrigerator for details on how to level your unit.
Check gaskets for proper seal. Clean, if necessary,
according to cleaning instructions
in owner's manual.
Check for internal obstructions
that are keeping door from
closing properly (i.e. improperly closed drawers, ice
buckets, oversized or improperly stored containers or
foodstuffs, etc.).
Unit is leaking
water
Plastic tubing was used to complete water
connection.
Amana recommends
using copper tubing for installation.
Plastic is less durable and can cause leakage. Amana is
not responsible
for property damage due to improper
installation
or water connection.
Ice forms in inlet tube to ice
Improper water valve was installed.
Check water connection procedure in your Installation
maker
Instructions.
Self-piercing and 3/_6"saddle valves cause low
water pressure and may clog the line over time. Amana
is
not responsible
for property
damage
due to improper
installation
or water connection.
Water pressure is low.
Water pressure must be between 20 to 100 pounds per
square inch to function properly. A minimum pressure of 35
pounds per square inch is recommended
for units with
water filters.
Water flow is slower
than
Freezer temperature is too high.
See the controls section in your owner's manual for
normal
assistance on how to adjust your controls. Freezer is
recommended
to be between 0 to 2°F (-18 to -!7°C).
Water pressure is low.
Water pressure must be between 20 to 100 pounds per
square inch to function properly. A minimum pressure of 35
pounds per square inch is recommended
for units with
water filters.
Improper water valve was installed.
Check water connection procedure in your Installation
3
Instructions.
Self-piercing and /_0"saddle valves cause low
water pressure and may clog the line over time. Amana
is
not responsible
for property damage due to improper
installation
or water connection.
i8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents