Electrical Wiring Diagram - Mr. Heater MHBF10LP Installation Instructions And Owner's Manual

Unvented lp-gas fired room heater
Table of Contents

Advertisement

Pressure Testing Heater Gas Connections:
1. Make sure that the heater supply piping system
is connected and has been leak tested as
described above.
2. Make sure control knob of heater is in OFF
position.
3. Open equipment shutoff valve (see figure 13).
4. Open propane/LP supply valve.
5. Check all joints from equipment shutoff valve to
control valve (see figure 14). Apply mixture of
liquid soap and water to gas joints. Bubbles
forming show a leak.
6. Correct all leaks at once.
7. Light heater (see Operating Your Heater, pages
11 and 12 for thermostat models or pages 9 and
10 for non-thermostat models). Check the rest
of the internal joints for leaks.
8. Turn off heater (see To Turn OFF Gas to
Appliance, page 12 for thermostat models and
page 11 for non-thermostat models).
9. Replace lower front panel.
Equipment
Shutoff Valve
Figure 13
Gas Meter
Figure 14
Open
Closed
Control Valve
Equipment
Shutoff Valve

ELECTRICAL WIRING DIAGRAM:

If any original wiring as supplied with the heater must be
replaced, it must be replaced with type AWG 105
or its equivalent except as indicated.
WARNING: Electrical Grounding Instructions: This
heater is equipped with a three-prong (grounding)
plug for your protection against shock hazard and
should be plugged into a properly grounded three-
prong receptacle.
OPERATING YOUR HEATER
NON-THERMOSTAT MODELS
MHIR10LP / MHBF10LP / TSIR10LP / TSBF10LP
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
A. This appliance has a pilot that must be lighted
by hand. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call you gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you can not reach your gas supplier, call the
fire department.
9
Installation instructions and Owner's Manual
Figure 15
o
C wire

Hide quick links:

Advertisement

Table of Contents
loading